5.
MAINTENANCE SCHEDULE (every 6 months)
Without 230 V~ power supply and batteries if present:
-
Clean and lubricate the gate's rotation pins and hinges
with neutral grease.
-
Check the resistance of the fixing points.
-
Check the value of the capacity of the motor condenser.
Reconnect the 230 V~ power supply and batteries if present:
-
Check the power adjustment.
-
Check that all commands and safety functions are ope-
rating correctly (photocells).
-
Check that the release system is working correctly.
-
Check that the batteries are working correctly (in conti-
nuity) if the VIVAH control panel with BATK2 battery kit
is present, by switching off the power supply and perfor-
ming several manoeuvres. Once performed, turn on the
230 V~ power supply again.
WARNING: For spare parts, see the spares price list.