Electrical Connections - DITEC CROSS18 Manual De Instalación Y Mantenimiento

Ocultar thumbs Ver también para CROSS18:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 28
4.

ELECTRICAL CONNECTIONS

GB
The electrical connections and starting are illustrated in the
installation manual of the control panel.
Note: the connection details of the motor and limit switches are
illustrated in fig. 4-5-6-7.
ATTENTION: Connect the yellow-green earth wire to the ap-
propriate terminal already connected to the motor as indicated
in the diagram.
yellow-green
All right reserved
All data and specifications have been drawn up and checked with the greatest care. The manufacturer cannot however take any
responsibility for eventual errors, ommisions or incomplete data due to technical or illustrative purposes.
CROSS18-19 - IP1984
5.
MAINTENANCE PROGRAM (every 6 months)
Disconnect the power supply and release the gearmotor (see
RELEASE INSTRUCTIONS):
-
Visually check that the gate, the fixing brackets and existing
structure have suitable mechanical strength and are in
good condition.
-
Check the gate-gearmotor alignment, the distance (2-3
mm) between the throat of the pinion, the crest of the rack
and the distance between the rack and rack stop (3 mm)
if present.
-
Clean the wheel's sliding guide, the rack and pinion of the
gear motor and slightly lubricate the rack and pinion of the
gearmotor. Manually check that the gate slides evenly and
without friction.
-
Check the capacity value of the condenser.
Connect the power supply and block the gearmotor (see RE-
LEASE INSTRUCTIONS operations):
-
Check that the limit switches are working correctly (the
gate should stop 20 mm before the stop).
-
Check the power adjustment.
-
Check that all control and safety functions are working
correctly.
ATTENTION: For spare parts, see the spares price list.