Whitehaven Fan Installation Instructions
INSTALL THE CANOPY
Loosen the 2 screws from the bottom of the mounting bracket.
Slide the canopy up to the mounting bracket and place the key hole on the canopy over the screw on the
mounting bracket. Turn the canopy until it locks in place at the narrow section of the key holes and secure it
by tightening the 2 set screws. Avoid damaging the electrical wiring prepared previously.
Pairing Transmitter and Receiver – when 2 or more DC ceiling fans are installed in one location
When two or more fans are located near each other, you may want to have the receiver/transmitter for each fan set to a
different code, so that the operation of one fan does not affect the operation of the other fan/s.
NOTE: Ensure that you have installed a single pole disconnection switch in the fixed wiring for each fan.
NOTE: Ensure power to the receiver is ON prior to pairing the transmitter with the receiver.
Transmitter / Receiver pairing for Ceiling fan 1:
Turn OFF the mains supply to the receivers of both ceiling fans 1 and 2.
Install the 3V DC battery in the compartment. Please make sure the polarity of the battery is correct. Fig.10
Turn on the power to receiver 1. Keep the power OFF to receiver 2. (Each ceiling fan must have its own isolation
switch, so that only the ceiling fan that needs to be paired with the transmitter will be ON).
Press and hold the "
the receiver of ceiling fan 1.
The fan will move slightly and stop to indicate the paring process is activated.
If the fan has light kit attached, the light will flash on and off to indicate the paring process is activated.
Turn ON and change the speed of the ceiling fan 1 by the transmitter to check the operation and successful paring.
8 | P a g e
FINISHING THE INSTALLATION
Fig. 9
USING YOUR CEILING FAN
" button of transmitter 1 for 3-5 seconds within 60 seconds of switching the power ON to