1.2.3 Temp.limit...
Hyst
T limit 1
If T-limit>60°, anti-scalding
protection must be instal
1.2.5 Max.temp...
T-max tank 1
1.2.6 Min.tempe...
Activation
T min Coll.1
Hyst. Coll.1
1.3 Basic functi...
Output parameter
Tube collector
Collector cooling
Commissioning
1.3 Basic functi...
Tube collector
Collector cooling
Commissioning
Delta T control
If the temperature in tank 1 exceeds the value
›T limit 1‹ the solar circuit pump is switched off
5.0K
unconditionally. The pump is not switched on again
60.0°C
until the actual temperature falls below the value
›T limit‹ by the hysteresis ›Hyst‹.
Example: T limit =60°C minus Hyst=5K
=> Reclosing temperature 55°C.
Continue via the menu item ›Max.temp.shutoff‹.
Maximum temperature of the tank 1, to avoid
excessively hot water in the tank; the tank in
59.0°C
question is only charged to its ›T max‹.
In case of collector overheating,
the tank can be charged up to ›T-limit‹.
Continue via the menu item ›Min. temperature‹.
To increase efficiency on charging the tanks, the
minimum temperature to be present at the
collector in question is entered via ›T min. Coll‹.
20.0°C
The relevant hysteresis value represents the difference
2.0K
between the switch-ON and switch-OFF temperature.
Return to ›Main menu‹. Continue with ›Basic functions‹.
The following items appear under ›1.3. Basic functions‹
next to the operation mode menus:
- ›Output parameter‹
- ›Collector cooling‹ ...
... and enhanced menus regarding the
- ›Delta T control‹
Call up the menu item ›Output parameter‹.