1.3.4 Cooling fu...
Activation
T max Coll.1
121.0°C
0 Welcome
You really want to
start commissioning?
No
1.3.5 dT-control
Activation dT1
dT1
dT ON 1
dT OFF 1
1.3.5 dT-control
dT OFF 1
dT targ. 1
Contl 1
step-wise
1.3.6 Fixed tem...
Control 1
Variant 1
step-wise
T-fixed 1
Here, collector cooling can be activated:
once the collector temperature ›T-max col1‹
is reached, the solar circuit pump operates
until the tank limit temperature is reached.
Return to ›1.3. Basic functions‹.
Continue with ›Commissioning‹.
Here, new commissioning can be started -
e. g. if a new hydraulic system is to be selected.
=> ›Commissioning mode‹ as of page 19.
Yes
Continue with ›Delta T control‹.
If control algorithms have been defined as ›dT‹
2.0K
under ›1.3.7 Output parameter‹, the
8.0K
appropriate outputs can be configured here.
4.0K
Via ›dT ON‹, the switch-ON temperature,
via ›dT OFF‹, the switch-OFF temperature
4.0K
and via ›dT targ.‹, the target differential
10.0K
temperature are set. (Differential temperature
between collector and tank, bottom).
Continue with ›Fixed T control‹.
If control algorithms have been defined as ›Fixed T‹
under ›1.3.7 Output parameter‹, the appropriate
outputs can be configured here.
In case of the fixed temperature control, the collector
is controlled to the preset temperature via a variable
pump delivery rate.
70.0°C
Continue with ›Protective funct.‹.
Professional mode
37