Cone Error Checking; Care And Handling - Agatec A510S Guía Rápida

Láser automático
Ocultar thumbs Ver también para A510S:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

1. Turn off the laser (17).
2. While keeping "Man" (19) pressed, turn on the laser (17).
3. After the 3 LEDs blink in sequence, release Man key.
4. The X LED (20) will blink.
5. Press the "MAN" key (19) to change to Z axis. The Z LED
(22) will blink rapidly for a bit and then slowly, indicating it's
ready to be calibrated in Z axis. The beam will not be rotating.
When it's in calibration mode, rotate the beam by pressing the
scan key, and make these adjustments:
1. Use the < and > keys (13 and 14) until the beam is perfectly
vertical and parallel to the plumb line.
2. Move the beam slightly so that the beam is over the plumb
line for the final check.
3. After completing the Z calibration, press the - or
to save it. The laser will shut off. If you are not sure of the cali-
bration and do not wish to save it, turn the laser off with the
On/Off key.

4.9 Cone error checking

1. Set up the laser about 2 feet (60 cm) away from a wall (A)
or a pole and 100 feet (30 m) from another wall or pole (B).
2. Turn the laser on.
3. After it has self-leveled, stop the rotation and mark the loca-
tion of the beam (center of the beam) on the near wall (A). Use
a detector if ambient conditions are too bright.
4. Rotate the laser 180°. Mark the location of the center of the
beam on the far wall (B).
5. Set up the laser about 2 feet (60 cm) away from the far
wall. After the laser has self leveled, mark the beam (B') near
the first mark (B).
6. Mark the location of the beam (A') on the other wall near the
first mark (A) in using if necessary the detector.
7. Compare the two sets of marks on the wall. If the difference
between AA'-BB' exceeds 1/4"(6 mm), contact your local serv-
ice center.
20
CAUTION
Using of controls or adjustments of procedures other than those
specified herein may result in hazardous radiation exposure.
The A510S is a precision instrument which must be handled
with care. Avoid shock and vibrations. Always store and trans-
port the laser and its accessories in the carrying case.
Although weather resistant, you must always keep your laser
and its accessories dry and clean after using. This will increase
.
the battery life.
key (15)
Do not store your laser at temperatures below -4°F (-20°C) or
above 176°F (80°C) because some electronic components
could be damaged.
Do not store your instrument in its case if the instrument or the
case are wet, to avoid water condensation inside the instru-
ment. To maintain the precision of your A510S, check and
adjust it regularly.
Keep the lenses of the apertures dry and clean. Use a soft cloth
and glass cleaner to clean them.
We recommend to regularly charge the batteries of the A510S.
Nevertheless, make sure to charge them only when they are out
of power or becoming so. Recharging batteries that are still use-
able will shorten their capacity.

5. Care and Handling

21

Publicidad

Tabla de contenido
loading

Tabla de contenido