KDP3 360
Presence detector
Detector with junction box KDP3/5 FP accessory (Optional purchase)
(See FIG.1-C)
Installation and wiring
Please disconnect power completely and read the entire instruction manual
carefully before installation
Select a proper location
• KDP3 can be installed at the height of 2 - 3m, it's recommended to install
it at the height of 2.5m to gain the optimal detection pattern, the detection
range can reach up to the diameter of 8m and 360o detection angle
(See FIG.2).
Top view
Φ8m
Φ4m
• Pay attention to the walking direction in the test proceeding. It is more
sensitive to movement across the detector and less sensitive to movement
directly toward to detector which will reduce the detection coverage (See
FIG.3).
Instructions manual |
Φ106
FIG.1-C
360
o
24
Φ110
Side view
4m
2m
Major Motion
Minor Motion
FIG.2
www.grupotemper.com
2m
4m