Orbegozo FDI 94 Manual De Instalación página 53

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

FDI 94 FDI 124 FDI 184 FDI 244 MANUAL DE INSTALACIÓN
TAKE NOTE OF FUSE SPECIFICATIONS
The air conditioner's circuit board (PCB) is designed with a fuse to provide overcurrent protection. The
specifications of the fuse are printed on the circuit board, such as: T3.15A/250VAC, T5A/250VAC, etc.
1. Prepare the cable for connection:
a. Using wire strippers, strip the rubber jacket from both ends of signal cable to reveal about 15cm (6in) of
the wires inside.
b. Strip the insulation from the ends of the wires.
c. Using wire crimper, crimp u-type lugs on the ends of the wires.
PAY ATTENTION TO LIVE WIRE While crimping wires, make sure you clearly distinguish the Live ("L") Wire
from other wires.
2. Open front panel of the indoor unit.
3. Using a screwdriver, open the wire box cover on the right side of the unit. This will reveal the terminal block.
WARNING: ALL WIRING MUST PERRFORMED STRICTLY IN ACCORDANCE WITH THE WIRING DIAGRAM
4. Unscrew the cable clamp below the terminal block and place it to the side.
5. Facing the back of the unit, remove the plastic panel on the bottom left-hand side.
6. Feed the signal wire through this slot, from the back of the unit to the front.
7. Facing the front of the unit, match the wire colors with the labels on the terminal block, connect the u-lug
and and firmly screw each wire to its corresponding terminal.
CAUTION! DO NOT MIX UP LIVE AND NULL WIRES: This is dangerous, and can cause the air conditioning
unit to malfunction.
LOCATED ON THE INSIDE OF THE INDOOR UNIT S WIRE COVER.