Lubrication
Switch off the power supplies.
S
Warning
Hot surface temperatures (up to 70 °C in normal operation, over 100 °C when
there is a fault) can cause burns.
S Remove the hot housing cover in order to lubricate the roller bearing only if
there is sufficient protection against burning (e.g. use protective gloves).
Unscrew the snap locking screws 5 a quarter of a turn.
S
Lubricate the roller bearing guide as shown in the table below.
S
Component
Lubrication
interval
Lubricating point
Lubricating
procedure
Grease
*)
For needle point nozzle with longitudinal or lateral exit (see Accessories")
Fig. 19
Festo HME−... 0604NH English
Roller bearing of the guide tubing
First lubrication:
Subsequent interval
with roller bearing grease LUB−KC1:
with roller bearing grease LUB−RN2:
at latest every 3 years
*)
Lubricating nipple aC
Move the guide tubing backwards and forwards by hand during
the lubricating process (the cavities will then be filled with oil to
an equal extent).
LUB−KC1 (or Centoplex−2−EP)
LUB−RN2 (or Rhenus Norlith STM2)
after 2500 km
every 400 km
every 2500 km