DISPLAY
DATA
StoP
no
ProS
invE
Foto
CFCh
no
Ch
tESt
no
Ft.Co
CoSt
Foto
CoSt
no
rESi
StAn
AP.Ch
Ch
AP
FC.En
StoP
no
rALL
ASM
0.5" ÷ 2.0'
no
SEnS
0 ÷ 10
Cont
tot.
SErv
APPr
no
Go
FinE
no
Si
900CT-101 FUNCTION TABLE
DESCRIPTION
STOP input
- STOP input not available
- STOP command stops the gate: START command starts moving in the
opposite direction
- STOP command stops the gate: pressing the START command gate continues
the motion
PHOTO 2 input
- Photocell is active in closing and also when the gate is still
- Not available
- Photocell is active during the closing
Test of safety devices
- Function not active
- Test enabled only for photocells
- Test enabled only for safety edges
- Test enabled either for photocells or for safety edges
Border input
- Input disabled (the control unit ignores it)
- Input enabled for conductive rubber ribbons
- Input enabled for standard safety ribbons with normally closed contact
- Input enabled in opening and closing phase
- Input enabled only in opening phase
- Input enabled only in closing phase
End of stroke inputs
- Input disabled (the control unit ignores it)
- Inputs enabled: the gate starts the slowdown phase (menu t.rAL) near
the limit switches
- Input enabled: the gate stops near the limit switches
Anti-skid
- Function disabled
Obstacle sensor level
Counter viewing
- Total number of completed cycles (views in thousands or in units)
- Number of cycles before the next request for service (such a number has
been rounded off to hundreds and it can be set up on 1000-step; in
case it is set up on 0, the request will be disabled and no will be viewed)
Automatic learning of the operation time
- Function disabled
- Start up of the automatic learning procedure
End of programming
- It does not exit from the program menu
- It exits from the program menu by storing the setup parameters
35
MEMO
DEFAULT
DATA
no
CFCh
no
no
StoP
1.0"
5
tot
no
no