Error
Possible cause
The LED on the
Cyclic check of the overload
system-specific
charging point illu-
minates red
The LED on the
Error on the charging station
system-specific
charging point is
permanently off
The LED on the
Charging point is defective
Bosch or Shimano
charging point is
permanently off
All LEDs off.
The permissible relative humidity in
the device is outside the permissible
range > 80%. Independent
safety shutdown of the
charging station.
The permissible temperature in the
device is outside the permissible
range 0 °C to +40 °C. Independent
safety shutdown of the charging sta-
tion.
The central voltage supply of the
charging station has been interrupt-
ed
The housing cover of the BCS SMART
has been opened without activating
the maintenance mode in the portal.
BCS SMART is dis-
BCS SMART is not connected to the
played as OFFLINE
portal
in the portal
BCS SMART
BCS SMART is not connected to the
not listed in
portal
the portal
36
Correction
►
Remove the overload.
►
Disconnect the charge cable from the
vehicle.
►
Switch off the power to the charging
station.
►
Have the error remedied by an authorised
qualified electrician.
►
Disconnect the charge cable from the
vehicle.
►
Switch off the power to the charging
station.
►
Have the error remedied by an authorised
qualified electrician.
►
Wait until the humidity outside reduces.
9
The charging station switches back on
automatically.
►
Wait until the temperature is within the
permissible operating temperature again.
9
The charging station switches back on
automatically.
►
If the error should continue to recur,
check the ambient conditions.
If the device is exposed to strong
solar radiation, ensure for shade.
►
Check the pre-connected fuse elements,
RC circuit-breaker (RCD).
►
Close the housing cover again. Switch on
maintenance mode:
►
Check the LED "backend" on the COM
module. If this does not illuminate,
establish a connection to the internet.
(see chapter starting up BCS SMART)
►
Perform a registration. (see
chapter starting up BCS SMART)