Electrical Connections - RIB RED Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

G
B
RADIO EDGE DEVICE is EN13849-2:2008 Standard-compliant device
and it's a Class-2 safety system if connected to a RIB control board
equipped with safety strip AUTOTEST output.
RADIO EDGE DEVICE allows to build a safety system made with one
or more safety strips fixed to the moving leaf/shutter without having to
use cable-reel. In fact, it consists in AGG5501 RADIO EDGE RECEIVER
and up to six ACG6202 RADIO EDGE TRANSMITTERs with a radio
communication based on a 868.3MHz RIB protocol.
The safety strips connections, their working states and the transmitters
battery charge levels are checked constantly.
The RED is suitable for both Normally Open (NO) or Normally Closed
(NC) safety strips.
POINT A

- ELECTRICAL CONNECTIONS

The RADIO EDGE DEVICE system is made up of the following:
R
ADIO EDGE RECEIVER code ACG5501
It receives signals sent by RADIO EDGE TRANSMITTERs (maximum 6)
and manages them together with the gate/door electronic control board.
J1
A*/D+
A/D-
A/D+ TEST
ALARM
EDGE
COM
OPEN
J2
AERIAL
JP1
A/D+ TEST
-
+/~
S1
PROG. RX
BUZZER
LED
DL1 (red)
- If OFF, indicates that the battery is flat and needs to be
replaced
DL2 (red)
- If OFF, indicates that the safety-strip is engaged by an
obstacle
DL3 (red)
- Available for future application
DL4 (yellow) - If ON, the control board power supply is functioning
RELAY
K1 ALARM contact (NC)
K2 EDGE contact (NC)
K3 Available for future application
TWO-COLOURS GREEN AND RED STATE OF FUNCTIONING LEDS
EDGE 1 - RADIO EDGE TRANSMITTER 1
(OFF correct functioning, GREEN safety strip engaged, RED state of alarm)
EDGE 2 - RADIO EDGE TRANSMITTER 2
(OFF correct functioning, GREEN safety strip engaged, RED state of alarm)
EDGE 3 - RADIO EDGE TRANSMITTER 3
(OFF correct functioning, GREEN safety strip engaged, RED state of alarm)
EDGE 4 - RADIO EDGE TRANSMITTER 4
(OFF correct functioning, GREEN safety strip engaged, RED state of alarm)
EDGE 5 - RADIO EDGE TRANSMITTER 5
(OFF correct functioning, GREEN safety strip engaged, RED state of alarm)
EDGE 6 - RADIO EDGE TRANSMITTER 6
(OFF correct functioning, GREEN safety strip engaged, RED state of alarm)
Positive power supply input +12/24Vac/dc
Negative power supply input -12/24Vac/dc
Safety strip SELFTEST power supply input
+12/24Vac/dc
Output flat battery warning contact (NC)
Output safety strip signal (NC) to the EDGE
input of the gate/door RIB control board
Common contact
Available for future application
Aerial connection (optional)
See RIB ELECTRONIC BOARD table below to
select:
SELFTEST mode selection jumper
SELFTEST mode selection jumper
Programming button
Warning and alarm state signal
L
EGISLATION ANS REGULATION ON AUTOMATIC GATES
AND DOORS
The Technician who has in charge the installing, must ensure that RADIO
EDGE DEVICE is connected, as explained in the EN12453 Standard at
section 5.1.1.6 (e and f), to a gate/door electronic control board able to
run operation control before the gate/door shutting movement (safety strip
SELFTEST).
Use RIB actuators, RIB electronic boards equipped with safety strip
SELFTEST and RIB safeties, in order to perform installation in compliance
with the Legislation and Regulation in force.
Once installation is complete, the operator must ensure the machine is
EN13241-1-compliant.
RIB shall not be held liable for any damages caused by misuse or
wrongful or unreasonable use of the product.
J2
JP1
J1
CNT 1 - Available for future application
CNT 2 - Available for future application
CNT 1 - Available
CNT 2 - Available
SW1 MICRO-SWITCHES
1 ON to enable RADIO EDGE TRANSMITTER 1
2 ON to enable RADIO EDGE TRANSMITTER 2
3 ON to enable RADIO EDGE TRANSMITTER 3
4 ON to enable RADIO EDGE TRANSMITTER 4
5 ON to enable RADIO EDGE TRANSMITTER 5
6 ON to enable RADIO EDGE TRANSMITTER 6
7 Available for future application
8 Available for future application
16
16
16
16
S1
SW1

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Acg6202

Tabla de contenido