Electrical Connections - RIB MASTER Wi-Fi Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

G
B
RADIO EDGE DEVICE is EN13849-2:2008 Standard-compliant device and it's
a Class-2 safety system if connected to a RIB control board equipped with
safety strip AUTOTEST output.
RADIO EDGE DEVICE allows to build a safety system made with one or
more safety strips fixed to the moving leaf/shutter without having to use
cable-reel.
It consists in a radio communication based on a 868.3MHz RIB protocol.
The safety strips connections, their working states and the transmitters battery
charge levels are checked constantly.
The RED is suitable for both Normally Open (NO) or Normally Closed (NC) safety
strips.
POINT A

- ELECTRICAL CONNECTIONS

J3
EDGE
J4
AERIAL
JP2
JUMPER
DL1
red led
SW2
dip-switches Identification code switches
S2
PROG.TX
BT1-BT2-BT3
Input from the safety strip contact
868MHz Aerial connection (optional)
Safety strip contact type selection (NO normally
open or NC normally closed)
Radio transmission in progress
Transmitter programming button
Power supply input 4.5Vdc N°3 1.5V AA-type
batteries
LEGISLATION ANS REGULATION ON AUTOMATIC GATES AND DOORS
The Technician who has in charge the installing, must ensure that RED is
connected, as explained in the EN12453 Standard at section 5.1.1.6 (e and f), to
a gate/door electronic control board able to run operation control before the gate/
door shutting movement (safety strip AUTOTEST).
Use RIB actuators, RIB electronic boards equipped with safety strip AUTOTEST and
RIB safeties, in order to perform installation in compliance with the Legislation and
Regulation in force.
Once installation is complete, the operator must ensure the machine is EN13241-
1-compliant.
RIB shall not be held liable for any damages caused by misuse or wrongful or
unreasonable use of the product.
J4
JP2
DL1
14
J3
S2
SW2

Publicidad

Tabla de contenido
loading

Tabla de contenido