YSRWJ-...-A
4. Fix the position of the positioning element
with a mandrel/open-end spanner and at
the same time tighten the lock nut on the
side of the capstan nut again (tightening
torque of lock nut see "Fitting mechanical
components").
S
Start a test run at low frequency and at
low impact speed.
S
Accelerate the work load in steps until the operating speed is reached.
Please refer to the calculations for your application for these speeds.
The shock absorber must not strike hard against the stop.
S
Conclude the test run.
6
Operation
Please note
If the shock absorber is not used to its full extent, there will be an increase in
the oil leakage.
Make sure that the shock absorber is operated with an energy utilization of at
least 25 % to max. 100 %.
The recommended range lies between 50 and 80 %.
A
A = not permitted B = permitted C = optimal
Fig. 13
S
Take into account the fact that the viscosity of the hydraulic oil diminishes
during operation due to the friction warmth which arises.
The shock absorber can therefore break through after a long period of
operation.
18
B
C
Fig. 12
B
A
Festo YSRWJ-...-A 0008NH English