Receiver
Display
OFF
Flashing yellow
Flashing red
Flashing yellow
OFF
OFF
Flashing red
Flashing yellow
OFF
Flashing yellow
OFF
Flashing yellow
OFF
Flashing yellow
Red ON
OFF
OFF
OFF
OFF
Flashing yellow
Flashing green
Flashing yellow
OFF
Flashing yellow
OFF
OFF
OFF
OFF
2TLC172297M0201
2015-09-10
Description
OSSD error
EDM error
Microprocessor error
Override possible
Optical error
Integrated lamp error
Power supply error
Main microprocessor error
10
Action
- Check the wiring and connections of the
OSSD outputs. Make sure that there is no
short-circuit between them or with the supply
voltage. See also "Connection Example".
- Check that the load characteristics are in
accordance with paragraph "Technical data"
of the Instruction manual.
- Check the wiring and connections of the
EDM, as well as the time sequence (see the
Time chart).
- Switch the devices off and on; if the error
persists, replace the external switching
device.
- Check the position of the configuration dip-
switches. Dip-switches 5-8 shall be in the
same position as dip-switches 1-4.
- Switch the devices off and on; if the error
persists, contact your ABB Jokab Safety
representative.
- This is NOT an error.
- Activate the Override function to remove the
material from the detection zone.
- Check the alignment.
- Switch the devices off and on; if the error
persists, contact your ABB Jokab Safety
representative.
- Switch the devices off and on; if the error
persists, contact your ABB Jokab Safety
representative.
- Check the wiring and connections of the
power supply. Check that its value is within
the allowed range.
- Switch the devices off and on; if the error
persists, contact your ABB Jokab Safety
representative.