Safety information
Warning! For a correct and safe use of Orion2 Extended light grids, the following points must be observed:
The stopping system of the machine must be electrically controlled.
This control system must be able to stop the hazardous movement of the machine within the total machine
stopping time T as per paragraph "Minimum installation distance" of the instruction manual, and during all working
cycle phases.
Mounting and connection of the AOPD must be carried out by qualified personnel only, according to the
indications included in the special sections of the instruction manual and in the applicable standards.
The AOPD must be securely placed in a particular position so that access to the hazard zone is not possible
without the interruption of the beams, see paragraph "Installation" of the instruction manual.
The personnel operating in the hazard zone must be well trained and must have adequate knowledge of all the
operating procedures of the AOPD.
The RESET button must be located outside the hazard zone because the operator must check the hazard zone
during all the reset and override operations. It must be impossible to reach the button from the hazard zone.
The external lamp signaling that muting is active must be visible from all operating sides.
Please carefully respect the mounting instructions for the muting sensors, see paragraph "Muting" of the
instruction manual.
If the external device monitoring (EDM) function is to be used, it must be activated with the dip-switches.
Please carefully read the instructions for the correct functioning before powering the AOPD.