Descargar Imprimir esta página

Keypad Symbols - Tyco DSC PowerSeries neo HS2ICONX Serie Instrucciones De Instalación

Publicidad

Idiomas disponibles

Idiomas disponibles

Table 13: Wireless Device Placement Test Modes
Test wireless devices individually by
001-128 Test wireless zones
zone.
Test each enrolled wireless repeater.
520
Test all repeaters
521-528 for repeaters 1-8.
Test each enrolled wireless siren.
550
Test all sirens
551-556 for sirens 1-16
Test individual wireless keys. Once in this
Test all wireless
section, press a button on the wireless key
600
keys
to begin the test.
601-632 for wireless keys 1-32.
Test each enrolled keypad
700
Test all keypads
701-716 for keypads 1-16.
Two test results are provided:
24-hour: Average results of signal strength testing over a 24-hour
l
period.
Now: Signal status results of the current test.
l
During testing, the Ready and Armed LED's flash to indicate data is being
received. A flashing Trouble LED indicates RF interference. The fol-
lowing status indicators may be displayed:
Table 14: Wireless Device Status Indicators
LCD
Status
Strong
Strong signal strength
Good
Good signal strength
Poor
Poor signal strength
The device is operating in 1-way mode only.
1-Way
The alarm panel cannot configure or control
the device
Not
Displayed as the Now result if no test was
Test
performed.
Always displayed as the 24-hour result when
None
testing wireless keys.
NOTE: For UL/ULC installations, only STRONG signal levels are
acceptable.
Troubleshooting
1. When attempting to assign a zone number to a wireless device, the
keypad responds with a long beep.
Ensure that the keypad is properly connected to the Corbus.
l
2. After entering the ESN of a wireless device, then tripping it, the
keypad does not indicate the zone is open.
Ensure the ESN has been entered correctly.
l
Ensure that the zone is enabled for the partition (if partition pro-
l
gramming is used).
Ensure that the wireless zone is not assigned to a zone used by
l
HSM2108 modules, an on-board zone or a keypad zone.
Ensure that the zone is programmed for something other than "Null
l
Operation".
3. "Poor" or no results are received from a module placement test.
Verify that you are testing the correct zone.
l
Verify the device is in range of the keypad. Test the device in the
l
same room as the receiver.
Confirm that the keypad is properly connected to the Corbus.
l
Check that the zone is being tested correctly. Refer to the instructions
l
that came with the device.
Check that the batteries are working and installed correctly.
l
Look for large metal objects that may be preventing the signal from
l
reaching the keypad.
The device must be located where consistent "Good" results are
l
obtained. If several devices show "Poor" results, or if panic pendants
and wireless keys operate inconsistently, move the receiver.
For systems compliant with EN50131-1 and EN50131-3 the HS2LED
keypad shall be used in conjunction with an LCD type keypad (HS2LCD
(P) or HS2LCDRF(P)8 or HS2LCDWF(P)8) in order to be able to review
logged events and also to allow overriding of conditions that inhibit setting
of the alarm system. The HS2LED keypad alone cannot support these func-
tions.
Repeater [905]

Keypad Symbols

Repeater 1
Repeater 2
Table 15: Keypad Symbols
Repeater 3
Repeater 4
3
4
1
2
Repeater 5
Repeater 6
8
9
5
6
13
7
14
15
16
17
10
11
12
Chime – Turns on when Door
Memory – Indicates that alarms
1
10
Chime is enabled and off when
are in memory.
Door Chime is disabled.
Fire – Indicates that fire
Away – Indicates that the
2
11
alarms are in memory.
panel is armed in away mode.
Clock Digits – These digits
indicate the hour and minutes
Stay – Indicates that the panel
12
when the local clock is active,
is armed in stay mode.
and also identify the zone when
3,4,5
the OPEN or ALARM icons are
active. These digits scroll one
Night – Indicates that the
zone per second from the lowest
13
panel is armed in night mode.
zone number to the highest
when scrolling through zones.
1 to 8 – These numbers display
Ready Light (green) – If the
6
toggles or digits in binary while
14
Ready light is on, the system
they are needed.
is ready for arming.
Bypass – Indicates that there
Armed Light (red) – If the
7
are zones automatically or
15
Armed light is on, the system
manually bypassed.
has been armed successfully.
Open – When zones are opened,
System Trouble – Indicates
8
this icon will turn on and the
16
that a system trouble is active.
open zones are displayed.
Program – If the system is in
Installer's or User's Pro-
gramming, or the keypad is
busy, this icon flashes. If an
AC – Indicates that AC is
9
17
access code is required while
present at the main panel.
accessing star menus, this LED
is on steadily to indicate that
the code is required.

Publicidad

loading