Installation; Connecting The Piping - LG MFL68280101 Manual De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation

Installation
[Wall mounted / ART COOL Mirror]

Connecting the piping

# Standard / Artcool Mirror Type
1. Prepare the indoor unit's piping and drain
hose for installation through the wall.
2. Remove the plastic tubing retainer(see the il-
lustration on the right) and pull the tubing and
drain hose away from chassis.
3. Route the indoor tubing and the drain hose to
the required piping hole position.
4. Insert the piping, drain hose, and the connect-
ing cable into the piping hole.
5. Insert the connecting cable into the indoor unit.
• Don't connect the cable to the indoor unit.
• Make a small loop with the cable for easy
connection later.
6. Tape the tubing and drain hose.
For right rear piping
7. Indoor unit installation
• Hang the indoor unit from the hooks at the
top of the installation plate.
• Insert the spacer etc. between the indoor
unit and the installation plate and separate
the bottom of the indoor unit from the wall.
14 Multi Air Conditioner
Tape
Connecting
pipe
Drain hose
For left rear piping
Indoor unit
Installation plate
80(3 5/32)
Drain pipe
Spacer

Publicidad

Tabla de contenido
loading

Tabla de contenido