Preparing the calibration check
It is possible for you to check the calibration of the laser. To do this, position the device
midway between 2 walls, which must be at least 5 metres apart. Switch the unit on
and use the SensoLite to define the marking points. For optimum results, please use a
tripod.
1. Mark point A1 on the wall. (Use spot mode.)
2. Turn the device through 180° and mark point A2. You now have a horizontal
reference between points A1 and A2.
1.
A1
2.
Performing the calibration check
3. Position the device as near as possible to the wall at the height of point A1. Now
adjust the device in the X axis.
Note: Mark either levelling screw A or B as a reference screw. Align the unit only with
the other levelling screws.
4. Turn the device through 180° and mark point A3. The difference between points A2
and A3 is the tolerance for the X axis.
5. To check the Y axis, repeat steps 3 and 4.
3.
A1
4.
Note: If points A2 and A3 are more than 0,5 mm / 10 m apart on either the X or Y
axis, the device is in need of calibration. Contact your authorised dealer or else the
UMAREX-LASERLINER Service Department or follow the calibration instructions in the
manual.
BeamControl-Master BCM