4.2- Wiring for power line, flashing light and electric motor:
4.3- Wiring for 24V outputs:
Second radio channel or photo-test output
Output for electrical lock
Terminal number Description
1-2-3
Power line
4-5
Output for flashing light
6-7-8
Output for powering the electric motor 1
(pedestrian)
9-10-11
Output for powering the electric motor 2
12-16
Second radio channel or photo-test output Second radio channel or photo-test output, can be selected with dip switch 1-3
13-14
Output for electrical lock control
15-16
Gate movement warning output
16-17
24 Vdc output
16-18
Flashing LED output
The sum of the absorptions of the 2CH, AUX, GND and LAMP outputs must not exceed 500mA.
EN
230/120 Vac
ELA3
230/120 Vac
-
-
M
M
M2
M1
M
M
Fig. 4
Fig. 5
+
-
-
Output for flashing LED
24Vdc output to power photocells and accessories
Output for viewing gate movement
Function
Power line 230/120 Vac (1=phase/ 2 = ground wire/ 3= neutral)
Output for powering the flashing light (230/120 Vac 60 W)
Output for powering the motor (6 = common / 7 = opens / 8 = closes) the capacitor is
to be connected in terminal 7 and 8 in parallel with the electric motor (max 300 W)
Output for powering the motor (9 = common / 10 = opens / 11 = closes) the capacitor
is to be connected in terminal 10 and 11 in parallel with the electric motor (max 300
W)
(12 = controlled GND, 16= permanent +24 Vdc, maximum load 200 mA)
Output for electrical lock 12Vacmaximum 15VA
Gate movement warning output, flashes slowly when opening, on steady with gate
open, flashes quickly during closing and off with gate closed (15 = controlled GND,
16 = permanent + 24 Vdc, maximum load 200 mA)
24 Vdc output to power photocells and accessories (17 = GND / 16 = + 24
Vdcmaximum load 200 mA)
Output for flashing LED (18 = controlled GND / 16 = + 24 Vdcmaximum load 200 mA)
17