4.10- Stop button connection: normally closed contact, opening the contact causes the gate to stop and suspends the automatic closing time (when the
+
button is not engaged, the STOP LED should be lit), if not used then jumper between COM and STOP:
-
COM
STPA
FOT
2CH
N.B. If the system has no photocells, sensitive edges or stop buttons (the PHOTO, STPA and STOP inputs must be jumpered), do not activate the
photo-test function and select the switch edge (dip switch 1.4 and 1.8 set off).
4.11- Connecting the aerial: The 17cm rod is supplied pre-wired, to increase the range connect the aerial ZL43 as shown in the figure:
5 - Description of the LEDS in the circuit:
SYMBOL
OPEN
Displays the status of the OPEN input (terminal number 19), if not engaged the red LED stays off (used to control opening
only, dedicated for the magnetic induction coil connection or timer)
AP/CH
Displays the status of the AP/CH input (terminal number 21), if not engaged the red led remains off
APED
Displays the status of the APED input (terminal number 22), if not engaged the red LED remains off
STOP
Displays the status of the STOP input (terminal number 24), if not engaged the green LED remains lit, if not used then
jumper between terminal COM and STOP
PHOTO
Displays the status of the PHOTO input (terminal number 25), if not engaged the green LED remains lit, if not used then
jumper between terminal COM and PHOTO.
STPA
Displays the status of the STPA input (terminal number 26), if not engaged the green LED remains lit, if not used then
jumper between terminal COM and STPA
DL8
Displays the programming status
6- Buttons in the circuit:
ON
ON
SYMBOL
AP/CH
1 2
3
4
5
6
7
8
1 2
P1
P2
Preliminary check:
After powering up the control unit the DL9 LED comes on for a second.
Check the diagnostic LEDs of the inputs, STOP, PHOTO and STPA must be on, if one of the normally closed contacts or one of the normally open contacts
is not in the rest state, the DL8 LED flashes quickly to indicate a fault.
Should one of the safety inputs (PHOTO, STOP, STPA) not be used, insert a jumper between COM and the input not used.
20
RX1
RX2
+
-
C NC NA
+
-
C NC NA
COM
STPA
FOT
2CH
Fig. 13
ON
ON
5
1 2
1 2
3
4
TX1
TX2
+
-
+
-
Fig. 12
Normally closed button
DESCRIPTION
6
7
8
DESCRIPTION
Controls opening and closing the gate
Press to enter travel programming
Press to enter radio controls programming or deletion
EN