Lenze EZAELN3 Serie Instrucciones Para El Montaje página 5

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Technical data
Enclosure
Insulation resistance
Class of insulation
Temperature
Storage
Transport
Operation
Pollution
Vibration resistance
Mounting location,
mounting position
Rated data,
conformity/approval
EDKLN3LR−4 DE/EN/FR/ES/IT 3.0
EN 60529
NEMA 250
EN 61800−5−1
EN 61800−5−1
EN 50178; IEC
61800−5−1;
Germanischer
Lloyd, general
conditions
In the control cabinet, recommended: Suspended with horizontal
alignment, ^ 13
(with greater masses, standing is also an option)
See nameplate
For power loss see table, ^ 12
IP 00
Protection against accidental
contact according to type 1
Overvoltage category III
> 2000 m: Overvoltage category II
H (permissible up to 180 °C)
In continuous operation with rated data, high surface
temperatures are reached!
−25 ... +60 °C
−25 ... +70 °C
−10 ... +55 °C (Temperature in the control cabinet)
Current derating from +40 ... +55 °C: 2.5 %/°C
Pollution degree 2
Acceleration−resistant up to 1 g
5
l

Publicidad

Tabla de contenido
loading

Tabla de contenido