Idiomas disponibles

When you place the moving shelves into the cabinet it is necessary taking into consideration the form
of the special holed conveyer panel that facilitates air circulation for a uniform temperature distribution:
WARNING:
1)The product must not obstruct the display area completely.
2)Avoid leaving shelves empty so as not to create turbulence
wich may prejudic regular refrige-rated air flow, and cause
needless energy consumption
During closing time let down the night curtain (if present)
to avoid an useless energy consumption.

PERIODICAL MAINTENANCE

Any further adjustments on the refrigerator necessarily require the electric plug to be removed.
Check periodically the supply cable in order to detect any damage. If the power supply cable is da-
maged, don't use the equipment and don't try to repair it: to prevent any risk, it must be replaced by
the manufacturer, by a member of the after-sales service staff, or anyway by a person having similar
qualifications.
In any case, none of the protective elements (the grill, the carter) must be removed by non qualified
staff. Absolutely avoid using the refrigerator without such protection.
The replacement of neon tubes must be carried out only by an Authorized Service Center.
The lamps have to be replaced by identical lamps only.

PUTTING INTO OPERATION

Check that the voltage on the identification
plate is the same as that of the network.
THE ELECTRICAL SUPPLY LINE TO
WHICH THE REFRIGERATOR WILL HAVE TO
BE CONNECTED IS TO BE PROTECTED BY
A VERY SENSITIVE DIFFERENTIAL SWITCH
(Rc=16A,Dc=30mA); IT IS ALSO TO BE LINKED
TO THE GENERAL EARTHING PLANT.
Earthing is necessary and compulsory by law. Abso-
lutely never use reduction units, patch cords, adapters
or multiple socket outlets to connect the counter.
DIRECTLY connect the equipment to the mains.
The manufacturer disclaims all responsability for any
damage to people or things due to incorrect observance
of this rule.