Description
The filter/regulator combines a general
purpose filter with a pressure regulator
in one compact unit. The filter is
designed to remove most liquid and
solid particles from the air supply. The
self-relieving pressure regulator is used
to adjust the outlet pressure between
0 - 150 psi.
Specifications
Regulator
style . . . . . . . . . . . . . . . . . . . . . . . relieving
Max. Temperature . . . . . . . . . . . . . .150˚ F
Max. Pressure . . . . . . . . . . . . . . . . . 150 psi
Air Inlet/outlet . . . . . . . . . . . 1/2 Inch NPT
Gauge Ports. . . . . . . . . . . . . . 1/8 Inch NPT
Filter Element . . . . . . . . . . . . . . .5 microns
Unpacking
After unpacking the unit, inspect
carefully for any damage that may
have occurred during transit. Make sure
to tighten fittings, bolts, etc., before
putting unit into service.
Safety Guidelines
This manual contains information
that is very important to know and
understand. This information is
provided for SAFETY and to PREVENT
EQUIPMENT PROBLEMS. To help
recognize this information, observe the
following symbols.
Danger indicates an
imminently
hazardous situation which, if not
avoided, WILL result in death or serious
injury.
Warning indicates a
potentially
hazardous situation which, if not
avoided, COULD result in death or
serious injury.
REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.
© 2010 Campbell Hausfeld/Scott Fetzer
hazardous situation which, if not
avoided, MAY result in minor or
moderate injury.
information, that if not followed, may
cause damage to equipment.
General Safety Information
This product is a part of a high pressure
Self
system and the following safety
precautions must be followed at all
times along with any other existing
safety rules.
Read this instruction manual
before installing this device
to the air supply system. Be
thoroughly familiar with
the controls and the proper use of the
equipment.
1. Safety glasses must be
worn during operation.
Always work in a well
ventilated area.
2. Do not exceed any pressure rating of
any component in the system.
3. Protect air lines from damage and/or
punctures.
4. Check air hoses for weak or worn
condition before each use. Make
sure all connections are secure.
5. Keep all nuts, bolts and screws tight
and ensure equipment is in safe
working condition.
For parts, product & service information
visit www.chpower.com
Filter - Regulator
Caution indicates a
potentially
Notice indicates
important
Figure 1
This product is specifically
designed for compressed
air service ONLY. Use with
any other material (liquid or gas) is
MANUAL
a misapplication and not permitted.
Use or injection of certain hazardous
liquids or gases in the system (such as
oxygen, alcohol or liquid petroleum
gas) will harm the unit and result in
a combustible condition or hazardous
external leakage. Misapplication will
void all warranties and manufacturer's
responsibilities.
regulators is limited. Install additional
pressure relief devices to alleviate
over pressurized conditions. Written
approval must be obtained from
manufacturer if this device is to be used
for life support systems or other non-
industrial applications.
Installation
Disconnect power and
release all pressure from the
system before attempting to
install, service, relocate or perform any
maintenance.
Model PA212603
80
60
100
5
7
40
120
3
.5
.3
.9
9
.1
10
1
1.1
140
11
bar
psig
160
The relief flow
capacity of
IN734200AV 5/10