Technical Service - Campbell Hausfeld PA212603 Instrucciones De Funcionamiento Y Manual De Piezas

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Filter • Pressure Regulator
Installation (Continued)
1. Locate the air flow direction arrow
(See Figure 2, detail). This arrow
shows the direction of the air flow,
i.e., it points to the outlet.
Flow direction arrow
Figure 2 Detail showing location of
flow direction arrow
2. Remove 1/8 inch NPT plug from the
plastic bag and 1/8 inch NPT gauge
from the white box. Use PTFE tape
on the threads and install securely in
the ports. (See Figure 3.)
3. Securely mount the filter /regulator
in a vertical position as close to the
air tool connection as possible. This
will maximize water removal and
minimize friction loss.
4. Verify the arrow points to the outlet.
(See Figure 2.)
5. Install the unit with the same pipe
size as the piping in use. Avoid using
www.chpower.com
unnecessary fittings, couplings, etc.,
that restrict airflow.
6. Connect the air supply to the inlet
port.
Operation
Ensure the
regulator adjusting
knob is unlocked when adjusting
pressure. The regulator will be damaged
if the knob is turned in the locked
position.
1. Before pressurizing system, make
certain the bowl is securely locked in
place by hand tightening the bowl
ring until it is snug.
2. Unlock the regulator adjusting knob
by pulling knob away from the
regulator.
3. Turn the regulator adjusting knob
counterclockwise until no load is on
the regulating spring.
4. Turn on the air pressure supply and
turn the adjusting knob clockwise
until the desired outlet pressure
is reached. Push the regulator
adjusting knob toward the regulator
to lock in desired pressure.
2
Model PA212603
Operation
Release all
pressure before attempting
to install, service, relocate or
perform any maintenance on
the air system. Personal injury and/or
property damage could occur.
Always
depressurize the
unit before removing the bowl. Personal
injury and/or property damage could
occur. If bowl is difficult to remove, it
may be under pressure.
FIlteR
1. Inspect and replace cracked,
damaged or deteriorated seals. Wipe
bowls with a soft, dry cloth to clean.
2. Replace or clean filter element
periodically. Remove the filter
element and tap filter on a hard
surface or use an air gun to blow out
residual dirt.
3. Drain bowls at least once per work
shift. To avoid spray or splatter,
cover bottom of filter with a cloth
and turn the manual drain.
4. Before placing the unit in service,
make sure the bowl is reinstalled
and securely locked in place.

technical Service

For information regarding the
operation or repair of this product,
please call 1-800-543-6400.

Publicidad

Tabla de contenido
loading

Tabla de contenido