Vimar 6948 Manual Do Instalador página 9

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 22
6948
OPERATING AND PROGRAMMING NOTES FOR INTERPHONES TYPE 62K4
AND TYPE 887B/1
Call signal
Interphones type 62K4 and type 887B/1 in the standard version emit the call
signal from the interphone loudspeaker. Obviously when the handset is picked
up, the signal is interrupted.
Procedure for the call parameter programming (only for Art. 887B/1).
The interphone generates the call signal and the respective time dwell internally:
the simultaneous push-button pressure on the interphone for a certain time allows
you to accede to the programming menu of the call parameters (audio frequency:
high, medium, low; signal time dwell: short, medium, prolonged).
To accede to the programming menu of the call parameters follow the under
mentioned steps:
a)
high frequency and short time dwell,
b)
high frequency and medium time dwell,
c)
high frequency and prolonged time dwell;
d)
medium frequency and short time dwell,
e)
medium frequency and medium time dwell,
f)
medium frequency and prolonged time dwell;
g)
low frequency and short time dwell,
h)
low frequency and medium time dwell,
i)
low frequency and prolonged time dwell;
Ringtone volume adjustment option (only for interphone 62K4)
Interphone type 62K4 also has the option of setting two different call ringtone
volumes; by setting jumper "CN6 - VOL" ("F" in the figure) the volume can be
modified as follows:
- jumper ON = ringtone volume high
- jumper OFF = ringtone volume low
Procedure for programming call parameters on interphone 62K4
1) Briefly press the programming button on the interphone.
2) Then press the
button until the red LED lights up, keeping it pressed
for a further 5 seconds until the red LED changes from a steady light to a
flashing light.
3) If the red LED doesn't start flashing, repeat the procedure from step 1.
4) The interphone starts to play the preset melody. By repeatedly pressing the
lock button "C" you can cycle through 9 melodies of different type and dura-
tion.
5) Once you have selected the desired melody, wait for the red LED light on the
interphone to go out, which confirms that the new setting has been stored.
Procedure for programming call parameters for interphone 887B/1
To access the call parameter programming menu:
1) Simultaneously press and hold down the two interphone buttons for approxi-
mately five seconds: the interphone will activate the first call (high frequency
and short duration);
2) By repeatedly pressing the F1 auxiliary function button (2nd button) you can
generate different types of call (frequency and duration).
3) Pressing the lock button (1st button) confirms and saves the selected call
type;
4) If neither button is pressed for 20 seconds, the interphone will exit call param-
eter programming mode and return to normal operating status.
Programming digital distributors Art. 949B from the entrance panel
1)
Briefly press button PS1on the digital distributor.
2)
Press then button PS2 on the digital distributor until the first of four LEDs on
the distributor illuminates.
3)
If the LED does not illuminate, repeat the above steps from point 1.
4)
Remove the handset from the interphone or monitor connected to terminals
A1 and A3 of the digital distributor in question and check the audio connec-
tion with the entrance panel.
5)
From the entrance panel or switchboard, key in the number with which you
wish to program the internal unit and route the call by pressing button "C".
6)
Wait for the LED switching off on the interphone for the programming con-
firmation.
7)
To program the remaining three internal units (interphones or monitors) con-
nected to the distributor in question, press button PS1 again and hold button
PS2 pressed down until the corresponding LED illuminates on the distributor
(second, third or fourth LED).
8)
The LEDS illuminate to indicate which internal unit is currently being pro-
grammed as illustrated in the table below, whereby:
LED 1 ¬ ® Terminals A1 and A3
LED 2 ¬ ® Terminals B1 and B3
LED 3 ¬ ® Terminals C1 and C3
LED 4 ¬ ® Terminals D1 and D3
9)
Program the remaining internal units following the same procedure outlined
above.
PROGRAMMING INTERPHONES, MONITORS AND DIGITAL DISTRIBUTORS
FROM SWITCHBOARD Art. 945B AND Art. 955
To program interphone and monitor user numbers with the switchboard, proceed
as follows:
-
Set the switchboard in "INTERNAL" mode.
-
Lift the switchboard handset and press button
lamp in key
illuminates.
-
Without replacing the handset on the switchboard, program the interphone,
monitor or distributor.
Programming interphones and monitors with internal coder Art. 887B, 6204,
6304, 6324, 6504
1)
Briefly press the programming button on the interphone or monitor (see fig-
ures below).
2)
Press then the door lock release button
programming button illuminates.
3)
If the LED does not illuminate, repeat the above steps from point 1.
4)
Remove the handset from the unit and check the audio connection with the
switchboard.
5)
From the switchboard, key in the number with which you wish to program the
internal unit and route the call by pressing button
6)
Wait for the LED switching off on the interphone for the programming confir-
mation.
7)
Program the remaining internal units following the same procedure outlined
above.
N.B.:
The audio line between the switchboard and interphone is only con-
nected when the led in key
off, press button
again until it illuminates. The LED remains illuminated for
the maximum conversation time set for the switchboard.
Programming digital distributors Art. 949B
1)
Briefly press button PS1on the digital distributor.
2)
Press then button PS2 on the digital distributor until the first of four LEDs on
the distributor illuminates.
3)
If the LED does not illuminate, repeat the above steps from point 1.
4)
Remove the handset from the interphone or monitor connected to terminals
A1 and A3 of the digital distributor in question and check the audio connec-
tion with the switchboard.
5)
From the switchboard, key in the number with which you wish to program the
internal unit and route the call by pressing button
6)
Wait for the LED switching off on the interphone for the programming confir-
mation.
7)
To program the remaining three internal units (interphones or monitors) con-
nected to the distributor in question, press button PS1 again and hold button
PS2 pressed down until the corresponding LED illuminates on the distributor
(second, third or fourth LED).
8)
The LEDS illuminate to indicate which internal unit is currently being pro-
grammed as illustrated in the table below, whereby:
LED 1 ¬ ® Terminals A1 and A3
LED 2 ¬ ® Terminals B1 and B3
LED 3 ¬ ® Terminals C1 and C3
LED 4 ¬ ® Terminals D1 and D3
9) Program the remaining internal units following the same procedure outlined
above.
N.B.:
The audio line between the switchboard and monitor is only connected
when the led in key
illuminates. Consequently, if the LED is switched off,
press button
again until it illuminates. The LED remains illuminated for the
maximum conversation time set for the switchboard.
EN
so that the indicator
until the LED near the
.
illuminates. Consequently, if the LED is switched
.
9