Program Mode
Graph of selected
program
Decrease program
number
Program Options
Edit Program
This option allows you to edit or create a program.
First, you must select the program to edit and then modify the points that make up the program.
Each program is composed of 9 points, each point consisting of 3 parameters:
1. Time (seconds)
2. Temperature (°C / °F)
3. Flow rate (%)
You can delete the last point of the program by selecting "-----" in the time parameter.
It should be taken into account that the regulation range permitted by the station is 150-450°C, whe-
reby it is not possible to create temperature ramps between room temperature (Toff) and 150°C.
The station can store up to 25 temperature programs.
The first three programs are edited by JBC as an example.
Copy Program
This option allows you to copy a program.
You must select the program source and its destination (where it will be copied).
Delete Program
This option will allow you to delete a previously selected program.
P r o g r a m 8
º
C
T e m p
380
Air
Time 125s.
w w w.jbctools.com
Selected program
º
C
Current temperature
100%
Selected air flow
Remaining time
Increase program
number
13