STEP 2: REMOVE OLD PARTS
A: REMOVE CONNECTOR
Remove water supply
connector from bottom of fill
valve by twisting connector nut to
the left (clockwise).
NOTE: Inspect water
supply connector. Replace it if
it is worn, or you don't know
how old it is, to prevent flooding
Towel
and property damage.
(Optional)
B: REMOVE OLD LOCKNUT
Use
green tool
to twist locknut
below tank to the left (clockwise) to
remove from fill valve.
C: REMOVE OLD FILL VALVE
Including refill tube, refill clip and
shank washer. Drain any excess
water into the back panel of
empty packaging by removing fill
valve from tank. (Pull fill valve up)
D: DISCONNECT
FLAPPER CHAIN
4
LEFT
LEFT
E: REMOVE LEVER
Unscrew tank lever nut by twisting
counterclockwise, remove nut and
pull lever from tank.
NOTE: May require pliers if stuck.
Pliers
(Optional)
F: REMOVE TANK FROM BOWL
green tool
Use
to unscrew nuts from
under the bowl and remove bolts
from tank.
NOTE: Bolts can be
loosened from inside tank.
Green Tool
Screwdriver
(Optional)
G: LAY TANK ON ITS SIDE
Place on a safe and secure surface.
H: REMOVE GASKET
Remove tank-to-bowl gasket from
below the tank.
NOTE: Keep gasket for identification on Step 4A.
I:
REMOVE FLUSH VALVE
LOCKNUT
Using
red
wrench, twist locknut
(counterclockwise) to remove.
Remove old flush valve from tank.