1
Activ8 360
4 ELEMENT
CEILING MOUNT
PASSIVE INFRARED DETECTOR
INSTALLATION INSTRUCTIONS
English
P/N 7102069 REV.B A.Y.
4
MOUNTING THE DETECTOR
Choose location most likely to intercept an
intruder. Refer to the detection pattern.
1. Hold the detector in your hand and
release the mounting plate by turning
it counter-clock-wise, and separate it
from the case (Fig. 1).
2. Insert the wires through the hole in the
center of the mounting plate (Fig. 2).
3. Mount the plate using the holes
marked mounting holes.
WIRE SIZE REQUIREMENTS
Use #22 AWG (0.5 mm) or wires with a
larger diameter. Use the following table to
determine required wire gauge (diameter)
and length of wire between the detector
and the control panel.
Wire Length
m 200 300
Wire Diameter mm .5
.75
Wire Length
ft. 800 1200 2000 3400
Wire Gauge
#
22
20
7
TERMINAL BLOCK CONNECTIONS
12VDC
RELAY TAMPER MEM
-
+
NC
NC
1
2
3
4
5
Run the cable through the cable entry hole
and connect the wires in accordance with
the following instructions:
Terminal 1 - Marked " - " ( GND )
Connect to ground of the control panel.
Terminal 2 - Marked " + " ( + 12V )
Connect to a positive Voltage output of
8.2-16 Vdc source (usually from the alarm
control unit).
Terminals 3 & 4 - Marked " RELAY "
These are the output relay contacts of the
detector. Connect to a normally closed
zone in the control panel.
Terminals 5 & 6 - Marked " TAMPER "
If a Tamper function is required connect
Activ8 360 FEATURES
∗ Fully sealed sensor chamber.
∗ VLSI Technology (Very Large Scale
Integration).
∗ Maximum RFI & EMI Immunity.
∗ 4 Element Pyro Sensor.
∗ Pulse Count.
∗ Sophisticated signal processing.
∗ Memory function.
∗ Hard Spherical Lens 360° coverage.
∗ Bidirectional temperature
compensation.
∗ Flourescent light stability.
INTRODUCTION
The Activ8 360 is a 4-element passive
infrared intrusion detector for use in
electronic security systems in ceiling
mount applications.
You will obtain optimum performance from
your Activ8 360 PIR detector by following
this manual.
FIG. 1 - Activ8 360 . EXTERNAL VIEW
OPEN
Separate cover
from base
400
800
1.0
1.5
18
16
these terminals to a 24 hour normally
closed protective zone in the control unit. If
the front cover of the detector is opened,
an immediate alarm signal will be sent to
MEM
the control unit.
Terminal 7 - Marked " MEM "
6
7
The alarm memory function allows the
identification of an alerting detector out of
multiple detectors connected to one (or the
same) zone of the control unit.
To enable this function, connect (switch
on) the M terminal to a switched +12 to
+16V
source (e.g. Arm / Disarm voltage
DC
output from the control unit.)
In case of an alarm, the memory function
stores the alarm event in the detector.
To identify the detector that alarmed,
disconnect (switch off) (grounded) the
voltage from MEM terminal.
The LED of the detector with the alarm
event in memory will light constantly until
memory function is reset.
To reset the memory function, switch on
and switch off the M terminal.
2
5
CLOSE
O
C
8
3
The Activ8 360 reduces false alarms to an
unprecedented minimal level due to its
effective elimination of background noises
and nuisance stimuli. The Activ8 360
employs Automatic Pulse Count making it
extremely adaptable to various
environments. The unique VLSI, using
sophisticated signal processing, makes this
detector virtually free of false alarms.
The Activ8 360 integrates VLSI & SMD
(surface mount device) to their full
advantage.
The detector is easy to install, with no
necessary adjustments.
HARD SPHERICAL LENS
The Activ8 360 is equipped with a special
hard lens. This lens is the latest
development in the security field and
complies with all the new standards
requirements. It gives wide coverage
patterns, even at low mounting heights. It is
especially immune to sunlight, halogen
lights and fluorescent lights and is
impervious to attack.
6
FIG. 2 - Activ8 360. INTERNAL VIEW
Pulse Count /
Terminal Strip
LED Enable Switch
Rubber
Insulation
Sensitivity/Range
Adjustment
9
PULSE COUNT /LED Enable DIP Switch
(Fig.3 and DIP-SWITCH Setting).
To change positions of the DIP-switch you
have to open the detector:
1. Turn the detector counter-clock wise
and separate it from the mounting
base.
2. Change position of the switch.
3. Close the detector and reinstall
assembly screws.