1
0
FIG. 3 - Activ8 360 BOTTOM VIEW
BLOCK CONNECTOR
LED
SWITCH FOR
SETTINGS
TAMPER
IMPORTANT:
1. Do not install the detector where it may
encounter water, steam or oil.
2. Do not aim the detector directly at
sources of rapid heating or cooling such
as: forced air ducts, heaters.
3. Be sure to locate the detector so that
valuables are well within its coverage
pattern.
4. Range may vary according to temp.
i
1
3
DIP-SWITCH SETTINGS
PULSE COUNT - DIP-SWITCH, "P" -
provides control for normal or high risk
operating environments.
Position "1" (OFF) - this setting is for a
stable environment.
Position "Auto" (ON) - the ACTIV8 360
will automatically select the appropriate
pulse count level (2 or 3) according to the
strength of the incoming signals. This
setting is for operation within a harsh
environment.
When an intrusion is detected, the LED
will activate and the alarm relay will switch
into alarm condition (open circuit) for 1.6
sec.
LED ENABLE - DIP-SWITCH, "L" -
to enable or disable the LED.
Position "ON" - LED enable.
Position "OFF" - LED disable.
1
6
TECHNICAL SPECIFICATIONS (CONT.)
Warm Up Period
20 sec
LED Indicator
LED is blinking
d
r u
n i
g
w
a
n
d
s
e
f l
O
N
d
r u
n i
Operating Temperature -20°C to+50°C
(-4°F to +122°F)
≥ 30V/m
RFI Protection
1
0
-
1
0
0
EMI Protection
50,000V of
e
e l
c
r t
c i
l a
i
t n
r e
e f
e r
g i l
h
n t
n i
g
h t
o r
u
g
h
Visible Light Protection stable against
h
a
o l
g
e
n
8 (
) t f
r o
g i l
t h
∅ ∅ ∅ ∅ 110mm x 45mm
Dimensions
( ∅ ∅ ∅ ∅ 4.33" x 1.77")
Weight
123 gr. ( 4.37 oz )
DETECTION PATTERN FOR Activ8 360
Installation Height
2.4m
PYROSENSO
3m
3.6m
Example: (See Fig. 4). If install at a height
of 3 m (10 ft) the detector will cover a
SENSITIVIT
circle of 20m (65.5 ft) at floor level, with an
ADJUSTME
effective detection range of 14m (45.9 ft) in
diameter.
Note: The detection range is the circle
pattern at floor level. The effective range is
the range at which an intruder will trigger
an alarm.
WALK TEST
After the installation, perform a walk test to
check that the detector operates properly.
FIG. 5 - LENS PATTERN
TOP VIEW
SIDE VIEW
0 (0)
m (ft)
2.4 (8)
3 (10)
3.6 (12)
r a
m
u
p
p
r e
o i
d
e t
t s
n i
, g
L
E
D
s i
g
l a
r a
m
0
M
H
z
Honeywell Security & Communications
(UK64)Newhouse Industrial Estate
Motherwell
n
c
e
f
o r
m
Lanarkshire
r o
p
o
w
r e
ML1 5SB
Tel +44 (0)1698 738200
g i l
t h
2
4 .
m
Fax +44 (0)1698 738300
e r
e l f
c
e t
d
Tech Support: +44 (0)844 8000 235
www.honeywell.com/security/uk/intruder
1
1
Detection
Diameter
(Effective Range)
8 ft
11m
36 ft
10ft
14m
46ft
12ft
16m
52ft
1
4
20m (65.6ft)
10
6.6
3.3
0
3.3
6.6
10
32.8
21.6
10.8
0
10.8
21.6
32.8 ft
1
7
FIG. 4 - Activ8 360 DETECTION AREA
Ceiling
3m (10ft) high
Effective
Detection
Diameter
Floor
TECHNICAL SPECIFICATIONS
Power Input
Current Draw
Detection Method
Sensitivity
Detection Speed
Bi Directional
Temperature
Pulse Count
Alarm Period
Alarm Output
Tamper Switch
m
1
2
14m (46ft)
0.8m
(2.6ft)
20m (65.5ft)
1
5
8.2 - 16 Vdc
Active / Standby: 9 mA
4 (Four) element PIR
Δ2°C (Δ3.6°F) at
0
6 .
m
s /
e
c
2 (
f
s / t
e
) c
0.5 - 1.5 m/sec
1 (
5 .
-
5
f
s / t
e
) c
YES
1,2-automatic switch from
2
o t
3
d
e
p
e
n
d
n i
g
o
n
1.6 sec
N.C 28VDC 0.1 A
i w
h t
1
0
O
h
m
s
r e
e i
s
p
o r
e t
t c
o i
n
e r
s
t s i
r o
N.C 28VDC 0.1A with
1
0
O
h
m
s
r e
e i
s
p
o r
e t
t c
o i
n
e r
s
s i
o t
- r
o
p
e
n
w
h
e
n
c
o
v
r e
s i
e r
m
o
v
e
d
1
8