Performance data of the chronothermostat:
• 3 Levels of temperature that can be adjusted and limited (Comfort, Working and Economy) + 1 anti-freeze level set at 5 °C (excludable).
• operating mode:
Winter
• 4 factory-set programs according to average European use: 1 daily and 3 weekly.
• 1
P 05
program that can be set according to defined personal requirements (minimum setting time is ½ h).
•
P 06
"HOLIDAY" program for the current program to be suspended for a set period of time (max. 999 hours).
• the set Comfort, Working and Economy temperature can be modified at any time.
• optional manual mode (temporary or permanent).
• possibility of stopping the boiler / air conditioner for cleaning purposes (max 3 hours).
• possibility of changing the current hour, minutes and day.
• optional intelligent mode with a maximum of 2 hours before the system goes on.
• possibility of viewing the current time or room temperature.
• possibility of limiting the set temperature values.
• possibility to connect to a telephone programmer for remote control.
• displayed hours of operation (daily and total).
• adjustable temperature in differential mode ON/OFF (can be modified).
• possibility to activate the pump for 2 minutes every day (anti-scale cycle).
• possibility to turn the thermoregulation off completely (OFF).
• reset command to cancel saved data.
• system troubleshooting indicator (e.g. boiler or air-conditioner blockage).
• error indicators: out of range temperature, failed probe, malfunctioning system.
24
pg. 25
pg. 26
pg. 29
pg. 30
pg. 31
(heating) or
Summer
mode (air-conditioning-cooling).