7.2 - Anti-scale cycle
When this function is selected, the chronothermostat relay will intervene every day at 12:00
and activate the connected device (pump, valve) for 2 minutes in order to prevent scale from
forming and prevent seizure that could be caused by prolonged inactivity.
N.B.
: this function is factory-set to "Disabled".
To set this function press
OK
until
OFF
PU - -
(enabled function).
To activate the function, press
:
To deactivate the function, press
Press
OK
to confirm
and return to the set program.
7.3 - Total disconnection of the Anti-freeze temperature
This function allows the thermoregulation to be deactivated when operating with the anti-
freeze temperature
t
selected.
Enabled function:
when utilising the anti-freeze temperature
enabled with a fixed temperature setting of
Disabled function:
when utilising the anti-freeze temperature t , the thermoregulation is
disabled (use only for systems filled with anti-freeze fluid in circuit).
N.B.:
this function is factory-set to
"
enabled
mode (Winter).
To set this function press
t
until ON
5.0c
(disabled function).
To deactivate the function, press
To activate the function press
:
ON
Press
OK
to confirm
and return to the set program.
PU - -
appears on the display (disabled function) or
PU - -
ON
PU - -
:
OFF
t
, the thermoregulation is
+5 °C.
"
and can only be deactivated when in heating
5.0c
appears on the display (enabled function) or
ON
5.0c
:
OFF
5.0c
ON
OFF
OFF
Fig. 47
ON
PROG
DAY
R
ON
OFF
ON
Fig. 48
OFF
PROG
DAY
R
G
B
43