1 - TECHNICAL SPECIFICATIONS
Power supply:
Autonomous operation time:
Time remaining from when
"Battery Low" symbol appears:
Type of action, disconnection and device:
Type of output:
Software:
Nominal pulse voltage:
Telephone programmer input:
Cross-section of wires to terminals:
Insulation:
Protection degree:
Pollution rating:
Room temperature display range:
Operating temperature limits:
Storing temperature limits:
Temperature adjusting range:
Setting temperature resolution:
Displaying temperature resolution:
Thermal gradient:
Differential operation:
Updating temperature display:
Reference standard for CE mark:
Note:
when the room temperature blinks, display range (-5 °C or +39 °C) has been exceeded.
Err
indicates that heat control activity has been suspended due to probe error.
2
alkaline
batteries 1.5 V - mod. LR03 (AAA) 1.5 V 1050 mA/h
ENERGIZER batteries are recommended
approx. 12 months
approx. 1 month
1 / B / U / Electronic
relay with single-pole changeover contact, voltage free,
COM / NO /
NC
- 8(2)A / 250 V~
Class A
4 kV
for NO contact, zero potential
2
min. 0,75 mm ÷ max. 1,5 mm
Class II
IP 30 / wall mounted
Normal
-5 °C ÷ + 39 °C
-5 °C ÷ + 55 °C
-10 °C ÷ + 65 °C
from +5 °C to +39 °C
0,5 °C
0,1 °C
max 1 °K/15 min.
adjustable T from 0.2 °C to 2 °C (factory-set at 0.6 °C)
Once every 60 seconds
LVD EN60730-2-7 EN60730-2-9
DURACELL or
2
EMC EN60730-2-7 EN60730-2-9
G
B