GAS FRYER
These installation instructions refer to the gas
Fryer unit, Category II2H3+.
The self-adhesive polyesterdata plateis behind the
control panel (inside the appliance). It contains the
following information:
Model
Serial number:
Category:
Year of construction:
Nominal thermal capacity:
Type of construction:
Test base:
Connection pressure:
G 30
G 20
Consumption:
G 30
G 20
• The unit must be installed in a well ventilated room,
possibly underneath a hood.
• Only a qualified and authorized gas expert may
install and service the unit, connect it to the gas
mains, convert or adapt it to another type of gas
or eliminate any faults.
Prior to installation you should obtain authoriza-
tion from the local gas board to install the unit.
• Prior to connecting the unit, install a cutoff cock
upstream between the unit and the distribution
network.
• The unit can be placed on a work surface or may
be installed on the apposite base, which is supplied
as an optional. The appliance may be installed
alone or in a set.
Note: If the appliance is installed on a counter, it
GB IE

Unit characteristics

FR35G/0
FR70G/0
FR35G/G6
FR70G/G6
XXXXXX
II2H3+
XXXX
6,25 kW
12,5 kW
A
EN 203-1
28-30/37 mbar
20 mbar
0,49 kg/h
0,99 kg/h
0,66 m
3
/h
1,32 m
3
/h
GB
The supplementary plate is also made of self-ad-
hesive polyester and is affixed near the data plate; it
contains all information regarding the actual unit.
Model FR 35G/... is supplied with two burners
and a fitting for gas connection. Model FR 70G/... is
supplied with four burners and two gas connection
fittings.
The gas connection ramp corresponds to the ISO
7/1 prescriptions, it has a Ø 1/2" diameter
connection and is located at the rear or at the bottom
depending on the model.
Burners are made of chromed steel.
The unit is in stainless steel and fitted with 4 height-
adjustable feet.
All fittings have metallic seals, guaranteed by the
use of bicones. Gas pipes, from the ramp to the cock,
are made of galvanized steel while those from the
cock to the burner are made of copper.
Location
must be fixed by means of the brackets supplied.
Respect a minimum distance of 80mm between
the sides and back and any walls of inflammable
material or from any adjacent appliances.
If these distances are not respected, thermal
insulation is necessary.
Attention: The manufacturer shall not be held
responsible for damage caused by negligence in
following the operating and installation instructions
or by improper use.
In addition, the manufacturer shall not be held re-
sponsible for connections that are not made in accor-
dance with current laws.
Fire-fighting prescriptions must be strictly
abided by!