Descargar Imprimir esta página

Connections - TiSUN MULTIPLEX Advanced Manual Del Usuario

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 64
1.3

Connections

Inputs T1
Inputs T2, T3, T4, T7 bis T12 Sensor for tank, collector or additional functions
Input T5
Input T6
VFS input (Duplex)
VFS input (Multiplex)
RPS input
Outputs P1, P2, P4 and P5
Outputs P3, P6, P7, P8, P10
Output P9
RJ45 slot
*ATTENTION: As a savety feature, all critical parameters (system and Extra function) are not accessible any more after 4 hours
power on. If you want to modify these parameters, you must unplug and plug in controller. No settings are lost when unplugging, or
after a power failure.After 4 hours it is only possible to alter system optimization settings.
Collector sensor
Sensor for collector return (theoretical heat quantity metering), tank, collector or additional functions
Pulse flow meter (heat quantity meter), pulse 5 VDC
VFS flow and temperature sensor for computing output and energy (electronic heat quantity meter),
input voltage 5 VDC, flow output voltage 0.5 to 3.5 VDC, temperature output voltage 0.5 to 3.5 VDC,
flow measuring range 1 to 200 l/min
2 inputs for VFS flow and temperature sensor for system control (not for calculating output and
energy), input voltage 5 VDC, flow output voltage 0.5 to 3.5 VDC, temperature output voltage 0.5 to
3.5 VDC, flow measuring range 1 to 200 l/min
2 inputs for RPS pressure and temperature sensor (system control), input voltage 5 VDC, pressure
output voltage 0.5 to 3.5 VDC, temperature output voltage 0.5 to 3.5 VDC, pressure measuring range
0 to 10 bar
TRIAC output 230 V / max. 1 A, for solar and heating pumps, with speed control (modulated
phase control) Min. 2W load on TRIAC to switch, if a power relay or similar is used.
PWM signal 4-15 V / 100-4,000 Hz, for control and speed regulation of high efficiency pumps
Note: It is also possible to connect a valve to these outputs in conjunction with the resistance kit.
Relay output 230 V / max. 2 A, for solar and heating pump or valve
Floating relay output 230 V/max. 2 A, for solar and heating pump, valve or floating demands
Duplex-Multiplex digital interface
7