Efka Motor Parameter Settings (Puller Motor)
The parameters below are pre-programmed before the unit is shipped.
When replacing or installing a new Efka Controller, perform a master reset of the parameters
using the following instructions.
To Perform Master Reset of Parameters:
1. Power on holding down the "P" button till "COD" is displayed.
2. Press ">>" once and enter the number "591"
3. Press "E" twice and "093" is displayed.
4. Press "+" once, "094" is displayed.
5. Press "P" to exit programming mode with all default values.
To modify the default parameters according to the table below, use the following instructions.
1. Power on holding down the "P" button till "COD" is displayed.
2. Press ">>" once and enter the number "311"
3. Press "E" once and "2.0.0." is displayed this is a parameter
4. Proceed to the parameter to be changed and press "E"
5. The value now shows in the screen, adjust to desired value.
6. Press "E" to enter value and continue with parameter setting.
7. Repeat for other parameters, press "P" once when complete.
8. Run fusing head to save parameters before powering down
Parameter
Range
290
111
0-999
119
40911
153
0-50
161
220
20090
270
272
020-255
Front panel LED's:
LED 1: Off
LED 2: Off
LED 3: Off
LED 4: Off
LED 5: Off
LED 6: Off
LED 7: Off
LED 8: On, Stop at needle up
Value
0
Mode Of Operation. MUST SET THIS PARAMETER FIRST!
40
Maximum Speed when "129" is 0, 1, or 2
1
Linear Acceleration
35
Braking power at standstill
0-1
0=CW
Motor Rotation
5
Accelerating power of the drive
0-5
5
No handwheel sensor
Drive ratio between motor pulley and driven pulley. The
160
larger the number, the slower the motor RPM.
Technical Manual & Parts Lists
Description
19