Troubleshooting Procedures - Kohler K-669 Manual De Propietario

Ocultar thumbs Ver también para K-669:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Shower Temperature Adjustment (cont.)
Turn the detent collar counterclockwise.
Verify the temperature.
If the temperature is greater than 105° F (41° C):
Pull out the detent collar.
Turn the detent collar clockwise.
Verify the temperature.
Repeat the steps above until the desired temperature is achieved.

Troubleshooting Procedures

This troubleshooting guide is for general aid only. For warranty
service, contact your dealer or wholesale distributor.
Symptoms
1. Only hot or cold water from
outlet.
2. Fluctuating or reduced flow rate. Normal function of thermostatic
1041158-5-C
Probable Cause/Recommended
Action
a. Inlet supplies are reversed. See
"Reversed Inlet Supplies" section
of the Installation Guide.
b. No hot water reaching shower
control.
c. Check filter screens for blockage.
control when operating conditions
are unsatisfactory.
a. Check filter screens for flow
restriction.
b. Make sure that the minimum
flow rate is sufficient for supply
conditions.
c. Make sure that dynamic inlet
pressures are nominally balanced
and sufficient.
d. Make sure that inlet
temperature differentials are
sufficient.
e. Service stops are not fully
threaded in. Rotate both service
stops until fully threaded.
f. Check thermostatic performance;
renew thermostatic cartridge, if
necessary.
10
Kohler Co.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

K-679K-670K-680

Tabla de contenido