Troubleshooting (cont.)
Symptoms
3.
Constant water flow.
4.
Sporadic water flow.
5.
Sensor flashes once
approximately every
2 seconds. The
product continues to
operate.
6.
Sensor flashes once
approximately every
2 seconds. The
product does not
operate.
1124217-2-D
Probable
Recommended Action
Causes
B. Supply
B. Check incoming water
pressure is
pressure. Pressure should
low.
be at least 20 psi (137 kPa).
C. Aerator is
C. Remove the aerator and
plugged.
clean it. For
calcium/mineral deposits,
soak the aerator plastic
insert in a 50:50 mixture of
vinegar and water. Soak
only the insert and no other
components.
A. Filter is
A. Clean or replace the
plugged.
filter.
B. Diaphragm
B. If the diaphragm is cut
seal is
or torn, order a new
damaged or
diaphragm assembly. Clean
dirty.
or replace the diaphragm.
C. Solenoid is
C. Order and install a new
not working.
solenoid assembly.
A. The faucet
A. Verify that the faucet is
is angled
mounted according to the
incorrectly to
installation directions.
deck or
Ensure that the faucet is
misaligned
installed in a position that
with user
is above the rim of the sink.
area.
B. The wires
B. Remove the spout and
are pinched
verify that the wires are
or damaged.
tucked inside the spout
before reassembling.
A. The HEC
A. Replace the HEC.
power is low.
A. The HEC
A. Replace the HEC.
power is
insufficient to
allow the
product to
operate.
10
Kohler Co.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

K-7515K-7516K-7517K-7518K-7519K-45345 ... Mostrar todo