TWO SPEED PUMP TIMER
READ INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO
INSTALL TIME SWITCH. SEE WARNING ON FRONT PANEL –
Failure to comply with instructions could result in personal injury and/
or property damage.
INSTALLATION: UNIT IS TO BE INSTALLED BY A LICENSED
ELECTRICIAN
1. Remove knockouts from back, bottom or side of enclosure as required.
DO NOT USE TOP.
2. Mount enclosure to vertical surface only. Mount at eye level using screws or
other suitable fastening device.
a) You may not need to remove timer module from enclosure. To
remove the timer module, remove screws on either side of timer face and
lift module out.
b) Use top mounting tab first to support the enclosure then use the
mounted enclosure as a template for the bottom two mounting holes.
3. Bring supply and load wires in through knockouts.
4. Reinstall module if removed. Connect wires according to wiring diagrams
on inside case label.
5. Always replace insulator cover for terminals.
CAPABILITIES
24 Hour scheduling
High-speed ON, low-speed ON, and OFF settings
Total # - 9 events, 3 cycles per day
Minimum setting: 5 minutes
FEATURES
Daylight Saving:
Leap Year:
Display:
Manual Override:
Power Outage:
TORK DPC201
Automatic (can be adjusted)
Automatic compensation
LCD
Until the next scheduled ON or OFF
automatic operation then resumes
Permanent schedule retention
Supercapacitor maintains real time up to 4 days
reset button
1