Fitting the work load

Place the work load so that the tilting
S
torque of the force parallel to the move
ment axis and lever arm a" remains low.
Make sure that the loadings of the SLTE−...
S
are lower than the maximum permitted
values (see chapter Technical Specifica
tions" and Characteristic Curves" as well
as catalogue specifications).
Fasten the work load to the fastening threads with centring 8.
S

Fitting electric components

Avoid external influence caused by mag
S
netic parts in the vicinity of the reference
switch.
In this way you can ensure that the switch
functions faultlessly.
SLTE−...
Distance from SLTE−... of the same type L
with proximity switch type:
SME−10..−...
SMT−10..−...
Distance from SLTE−... of the same type L
with proximity switch type:
SME−10..−...
SMT−10..−...
Fig. 11
Place the reference switch only in the upper groove 2.
S
A groove sealed with a cover must not be used.
Festo SLTE−... 0501NH English