Installation
1
1. Affix the mounting template in the intended position (maximum height 3 meters).
2. Drill two mounting holes (3.4mm ø) according to the mounting template.
3. Drill one mounting hole (8mm ø) to run the wires through.
4. Remove the mounting template remove any burrs created.
Note:
Be sure to install the sensor where it will not be directly sprayed with rainwater.
Be sure that the mounting height is within the value of those in "Specification".
2
Remove the cover and fasten the main unit with the screws.
Plug the connector for the sensor to that for the cable.
PASAA2
3
Apply power to the sensor. Then, adjust each detection area. (See ADJUSTMENT)
Note:
Make sure you connect the cable correctly to the Control Unit ot the door before turning the power on.
4
1. Put back the cover on the sensor.
2. If wiring is to be exposed, break the knockout.
Gray
Gray
}
Power supply
Gray
12-30 V AC/DC
Gray
White
COM
White
Yellow
Activation
N.O.
Green
Yellow
N.C.
White striped
N.C.
Safety
Green striped
N.C.
Green striped
White striped
Detection area
A
2.20 (7'25/8")
2.50 (8'2 7/16")
B
0.13 (5 1/8")
0.15 (5 7/8")
C
0.45 (1'5 11/16")
0.51 (1'8 1 /16")
D
0.90 (2'11 7/15")
1.02 (3'4 3/16")
E
1.30 (4'3 3/16")
1.48 (4'10 1/4")
F
1.90 (6'2 13/16")
2.16 (7'1 1/16")
G
2.45 (8' 7/16")
2.78 (9'1 7/16")
H
1.76 (5'9 5/16")
2.00 (6'6 3/4")
I
1.11 (3'7 11/16")
1.26 (4'1 5/8")
X
0.09 (3 9/16")
0.10 (3 15/16")
The above are the values when the distance between the installation surface and the 1st row is X.
1st Row
2nd Row
3rd Row
4th Row
5th Row
: Emitting Spot
2.70 (8'10 5/16")
3.00 (9'10 1/8")
0.16 (6 5/16")
0.18 (7")
0.55 (1'9 5/8")
0.61 (2' 3/16")
1.11 (3'7 11/16")
1.23 (4' 5 /8")
1.59 (5'2 5/8")
1.77 (5'9 13/16")
2.33 (7'7 3/4")
2.59 (8'6")
2.97 (9'8 15/16")
3.30 (10'9 15/16")
2.16 (7'1 1/16")
2.40 (7'10 1/8")
1.35 (4'5 1/8")
1.50 (4'11 1/16")
0.11 (4 5/16")
0.12 (4 13/16")
A
B
C
D
E
F
I
H
G
[m (feet, inch)]