The instruction manual is downloadable from the site www.vimar.com
Petrarca
Description
Part No. 6204 is an interphone belonging to the DigiBus series with internal coding for 4 and 8 digit coding systems. It can be
combined with the monitors belonging to the Petrarca series (part No. 6000 and 6003) by means of brackets or transformation
kits. The lock button is enabled only if the interphone has been called. When the interphone is in the rest state, the same button
fulfils the function of calling the porter, and sending the decoding number to the switchboard. The supplementary functions F1,
F2, F3, F4, F5, F6, F7 and F8 can be used by means of the supplementary buttons, part No. 6C59, while the "user-absent"
function can be activated by means of part No. 6153. The interphone can also be connected to a supplementary speech unit
such as part No. 930D.
Connection terminal board
1
Digital line for transmission/reception.
3
Voice and call line.
4
Ground reference line (power supply).
5
Line +13.5V DC (power supply).
6
Interphone line ON (goes to ground when the interphone has been switched on by a digital call).
12 Supplementary voice line for 930D speech unit.
11 Line for door call.
Connectors
T1
For auxiliary functions F1 and F2 to be connected to a pair of buttons, part No. 6C59.
T2
For auxiliary functions F3, F4, F5 and F6 to be connected to a pair of buttons, part No. 6C59. The first button activates
functions F3, F4 and F5 cyclically; the second activates function F6.
T3
For auxiliary functions F7 and F8 to be connected to a pair of buttons, part No. 6C59.
Program. Reserved, to be used only as instructed by the manufacturer.
U.A.
For "user-absent" function, to be connected to part No. 6153.
Monit.
For connecting a monitor interconnection card.
BL,BI
Handset connection (blue and white wire)
C
Common wire for call loudspeaker
A+
Call louspeaker connection for maximum power
A-
Call loudspeaker connection for attenuated chime
Programming and operation
The following operations must be carried out only after the entrance panel has been programmed. To program the interphone
number, remove the cover, press the PRG button on the circuit board and hold down the "LOCK" button.
If the procedure has been effected correctly, the unit will assume programming mode with led (present on the interphone circuit
board) lighting up, at which point "LOCK" push-button (related to door lock) can be released. .
If the LED does not light up, the sequence must be repeated. The interphone handset will now enable communication with the
stairway panel so that the latter sends back the interphone code. As the code is transmitted from the panel to the phone, it will
be memorized by the unit and remain stored until further programming, even in the event of the panel being disconnected from
the power supply. The entryphone generates a call sound in confirmation of the programming operation. Hook the handset again.
In case of installations with several entries, the connector for the entrance panel interphone riser must be removed, leaving only
one entrance panel in operation for the programming phase.
This operation can be repeated any number of times, using other numbers between 0000 0001 and 9999 9999.
EN