Franke Roblin Windy Pro 900 Instrucciones De Instalación E Utilización página 12

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 24
GB
Do not dispose of on fire.
5
USEFUL HINTS
To obtain the best performance it is advisable to switch 'ON' the cooker hood a few minutes (in the
boost setting) before you start cooking and you should leave it running for approximately 15 minutes
after finishing.
IMPORTANT: NEVER DO FLAMBÉ COOKING UNDER THIS COOKER HOOD
Do not leave frying pans unattended during use as over-heated fat and oil might catch fire.
Do not leave naked flames under this cooker hood.
Switch 'OFF' the electric and gas before removing pots and pans.
Ensure heating areas on your hotplate are covered with pots and pans when using the hotplate
and cooker hood simultaneously.
6
MAINTENANCE
Before carrying out any maintenance or cleaning isolate the cooker hood from the mains supply.
The cooker hood must be kept clean; a build up of fat or grease can be a fire hazard.
Casing
Wipe the cooker hood frequently with a clean cloth, which has been immersed in warm water contain-
ing a mild detergent and wrung out.
Never use excessive amounts of water when cleaning particularly around the control panel.
Never use scouring pads or abrasive cleaners.
Always wear protective gloves when cleaning the cooker hood.
Metal Grease Filters
The metal grease filters absorb grease and dust during cooking to help keep the cooker hood clean
inside. The grease filters should be cleaned once a month or more frequently if the hood is used for
more than 3 hours per day.
To remove and replace the metal grease filters
Remove the metal grease filters one at a time by releasing the catches on the filters; the filters can
now be removed.
The metal grease filters should be washed, by hand, in mild soapy water or in a dishwasher.
Allow to dry before replacing.
Active Charcoal Filter
The charcoal filter cannot be cleaned. The filter should be replaced at least every three months or more
frequently if the hood is used for more than three hours per day.
To remove and replace the filter
Remove the metal grease filters.
Press against the two retaining clips, which hold the charcoal filter in place and this will allow the filter
to drop down and be removed.
Clean the surrounding area and metal grease filters as directed above.
Insert the replacement filter and ensure the two retaining clips are correctly located.
Replace the metal grease filters.
Extraction tube.
Check every 6 months that the dirty air is being extracted correctly. Comply with local rules and regula-
tions with regard to the extraction of ventilated air.
Lighting.
If the lamp fails to function check to ensure it is fitted correctly into the holder. If lamp failure has occurred
10

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Roblin windy pro 1000Roblin windy pro 1200

Tabla de contenido