  • MEXICANO, página 52
CV
Meaning
130 POM Switching Function Turnout 4, red
131 POM Pulse Width
132 POM Period
133 POM Switching Function Turnout 4, green
134 POM Pulse Width
135 POM Period
We recommend the following pulse widths und periods for our turnout mechanisms:
C Track turnout: 30%, 0,25 sec.
K Track turnout: 75%, 0,5 sec.
M Track turnout: 75%, 1 sec.
Automatic Turnout Circuits (CV 34 & CV 35)
Value Name
0
2 turnouts
1
Three-way turnout
2
Double slip switch
24
Value
Comment
0 – 142
Switches the "red" output for the fourth turnout
0 – 255
255 = 100 %
0 – 255
Time interval between the pauses; 1 = 0,05 sec.
0 – 142
Switches the "green" output for the fourth turnout
0 – 255
255 = 100 %
0 – 255
Time interval between the pauses; 1 = 0,05 sec.
Comment
Two outputs, one for each turnout, are switched in turn
4 outputs are linked together for a three-way turnout with 2 mechanisms
4 outputs are linked together for a double slip switch with 2 mechanisms