FIG. 5: Vacuum cutoff valve removal and cleaning
the waste tank thoroughly. This will help to prevent the
formation of damaging deposits and reduce the growth
of odor-causing bacteria.
3. Turn on Clean Extract mode and allow it to run for 5
minutes to help remove any moisture from the vacuum
motors and help ensure long vacuum life.
MAINTENANCE
WARNING: Unplug machine before
servicing. Possibility of electrical shock.
WARNING: Interior components may be hot
after operation. Let unit cool completely
before servicing.
DAILY OR AFTER EACH USE
Clean the solution inlet filter (Fig. 4). Loosen tank
retention nut (Fig. 1E) and open unit. Remove filter cover
and strainer screen (Fig. 4). Rinse strainer screen clean
in warm water. Replace strainer and retighten filter
cover.
Clean vacuum ball float valve (Fig. 5). Empty recovery
tank, then open recovery tank lid. Grasp valve assembly
and pull gently toward the front of the unit, taking care
not to distort the strainer screen. Rinse assembly clean
and make sure float ball moves freely inside assembly.
Clean recovery tank strainer (Fig. 6). Remove strainer
by gently rotating it and lifting upward. Rinse filter clean
with water and reinstall.
Reinstall strainer and vacuum ball float valve assembly
securely.
07-02091D F561-MP
FIG. 6: Recovery tank strainer
4
Slide filter
upward to
remove. Rinse
filter clean with
water and
reinstall.