Descargar Imprimir esta página

Thetford SANICON TURBO 600S Manual Del Propietario Y Instalación página 5

Publicidad

Assembly
!
4D
4A
K7
Ref.
Description
K1
Pump Assembly (K1a OR K1b)
K2
1.5" Discharge Hose Assembly (One end connects to pump,
other end connects to nozzle then RV dump station.)
K7
3" RV Inlet Hose (One end connects to pump, other end con-
nects to RV sewer outlet.)
4A
Gate Valves (black, gray, manual over-ride); number of valves
vary according to each RV setup
4B
RV Compartment
4C
RV Sidewall
4D
RV Sewer Outlet
®
SANICON
Turbo - Model 600S
Fig. 4
4B
K2
4C
K1
Install Pump
Prepare
Install
1.
2.
3.
4.
5
Only one bracket is used for the installation. Choose the
NOTICE
bracket that best suits your RV layout. If pump comes
with metal brackets, attach the adapter bracket with
installation screws (4x).
■ Flush all debris from holding tanks.
■ Close all gate valves
(4A)
■ Make sure installed unit will not interfere with the operation
of the gray and black water RV gate valve handles
Attach the bracket that best fi ts the RV layout to the pump.
Position the pump
!
NOTICE
AVISO
CAUTION
AVIS
ment fl oor or wall making sure that it is lower than
the sewer outlet
sewer outlet.
Fasten the base bracket to the mounting surface using ¼"
fasteners (not provided).
Connect the bayonet adapter to the RV's sewer outlet.
Make sure the inlet hose
kinks, traps, or excessive distance in the inlet hose. Trim
the hose, if necessary. Make sure the hose clamp is over
the rubber seal before tightening. Do not overtighten the
hose clamp when adjusting the hose length, as it may dam-
age the hose. Refer to Fig. 4.
If hose leaks at either end, tighten hose clamp
NOTICE
K1
i
.
(4A)
and bracket on the compart-
(K1)
and the inlet hose reaches the
(4D)
(K7)
is positioned properly. Avoid
(K7.1)
97573 Rev. E (01/08/18)
.
.

Publicidad

Capítulos

Solución de problemas

loading