10
Troubleshooting
Malfunction
No power at the
sensor
Lights do not switch
ON
Lights do not switch
OFF
Lights keep
switching ON/OFF
Lights switch ON
without obvious
movement
Warranty
STEINEL America warrants its products
against defects in material or workmanship
for a period of five years. STEINEL will
replace or repair the item provided that
it has not been altered or subjected to
abuse, accident, improper installation or
improper use. There are no obligations
M-11611-0
Cause
breaker has tripped; light switch is in
OFF position
short circuit
light level setting is in nighttime
mode during daytime operation
lamp burned out
power is off
detection zone not correctly adjusted
abundant heat from the fixture is
within detection zone and keeps
lights on as a result of temperature
change
set to 4 hour override mode
switched on light is within detection
zone
animals moving in detection zone
wind is moving trees and bushes in
the detection zone
cars in the street are detected
sudden temp changes due to
weather (wind, rain, snow) or exhaust
air from fans or open windows
Remedy
reset breaker, turn light switch
to ON position, check wiring
with voltage tester
check for proper wiring
connections
adjust light level setting
replace lamp
turn power on at circuit breaker
readjust
readjust zone or apply shroud
turn sensor off at switch
adjust detection zone or apply
shrouds, increase distance
adjust zone or apply shrouds
adjust zone or apply shrouds
adjust zone or apply shrouds
adjust detection zone or install
in a different place
or liabilities on the part of STEINEL for
consequential damages arising out of or
in connection with the use or performance
of this product or other indirect damages
with respect to loss of property, revenue,
or profit, or cost of removal, installation or
reinstallation.
www.steinel.net
(800) 852-4343