Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 15
Adjusting the detection zone
The detection zone can be limited to suit requirements.
The shrouds supplied with the light can be used to mask
out as many lens segments as you wish. This prevents
the light from being activated unintentionally, e.g. by
cars, passers-by etc., and allows you to target danger
Manual override function
If a mains switch is installed in the mains supply lead,
the light is capable of the following functions in addition
to the simple ON/OFF function:
Sensor operation
1) Switch light ON (when light is OFF):
Turn switch OFF and ON once.
Light stays ON for the period selected.
2) Switch light OFF (when light is ON):
Turn switch OFF and ON once.
The light goes out or switches over to sensor mode.
Technical specifications
Dimensions (H x W x D):
270 x 100 x 141 mm (L 626 LED)
270 x 328 x 141 mm (L 625 LED)
Mains voltage:
230 – 240 V, 50 Hz
Output:
L 625 LED: 8 W LED main lighting
1 W LED street number lighting
155 lm
L 626 LED: 8 W LED main lighting
150 lm
Colour temperature:
3200 kelvin (warm white)
LED life expectancy:
50.000 hours
Angle of coverage:
360° with sneak-by guard
Detection reach:
8 m all round
Twilight setting:
2 – 2000 lux
Time setting:
5 sec. – 15 min.
Basic lighting level:
0 or 25%, soft light start
Manual override:
4 hours, switchable
IP rating:
IP 44
Protection class:
I
Temperature range:
- 20° C to + 50° C
Operation / Maintenance
The SensorLight is suitable for switching light ON auto-
matically. Weather conditions may affect the way the
SensorLight functions. Strong gusts of wind, snow, rain
or hail may cause the light to come ON when it is not
wanted because the sensor is unable to distinguish sud-
Declaration of conformity
This product complies with
- Low Voltage Directive 2006/95/EC
- EMC Directive 2004/108/EC
- RoHS Directive 2002/95/EC
spots. The shrouds can be cut along the pre-grooved
vertical divisions. Then you simply clip them onto the
lens.
Manual override
1) Activate manual override:
Turn switch OFF and ON twice. The light is set to stay
ON for 4 hours (red LED lights up behind lens). Then it
returns automatically to sensor mode (red LED off).
2) Deactivate manual override:
Turn switch OFF and ON once. The light goes out or
switches over to sensor mode.
Important:
The switch should be actuated in rapid succession
(in the 0.5 – 1 sec. range).
den changes of temperature from sources of heat.
The detector lens may be cleaned with a damp cloth
if it gets dirty (do not use cleaning agents).
- 14 -

Troubleshooting

Malfunction
Cause
SensorLight without power
Fuse faulty, not switched ON,
break in wiring
Short circuit
SensorLight will not switch ON
Twilight control set to night-time
during daytime operation
Power switch OFF
Fuse faulty
Detection zone not properly
targeted
Internal electrical fuse has
been activated
(red LED flashing rapidly)
Mains terminal not connected
properly
SensorLight will not switch OFF
Continued movement within the
detection zone
Sensor unit is not properly
engaged
Basic lighting level does not go out
External light source
at about midnight as desired
(e.g. other motion detector or
light) inactivating the SensorLight
SensorLight will not switch OFF
Basic lighting level selected
completely
SensorLight switching ON when
Wind is moving trees and bushes
it should not
in the detection zone
Cars in the street are being
detected
Sudden temperature change due
to weather (wind, rain, snow) or air
expelled from fans, open
windows
Change in SensorLight reach
Differing ambient temperatures
Red LED flashing rapidly
Internal fuse activated
LED illuminated panel not operating
Terminal not pushed in all the way
LED illuminated panel OFF although
Programme 3 or 4 selected
it is dark
LEDs flickering
Local power grid
Functional Warranty
This STEINEL product has been manufactured with
great care, tested for proper operation and safety in
accordance with applicable regulations and then sub-
jected to random sample inspection. STEINEL guaran-
tees that it is in perfect condition and proper working
order. The warranty period is 36 months, starting on the
date of sale to the consumer. We will remedy defects
caused by material flaws or manufacturing faults. The
warranty will be met by repair or replacement at our own
discretion. The warranty shall not cover damage to wear
parts, damage or defects caused by improper treatment
or maintenance. Further consequential damage to exter-
nal items is excluded.
Remedy
Fit new fuse; switch ON mains
switch; check wiring with voltage
tester
Check connections
Re-adjust (control
)
Switch ON
New fuse, check connection if
necessary
Re-adjust
Switch SensorLight OFF and
back ON again after 5 sec.
Firmly press terminal together
Check detection zone and
re-adjust if necessary
Lightly press sensor unit to
clip it into place
Shade SensorLight from extrane-
ous light, observe SensorLight for
several days as it takes time to
return to the correct value
Turn programme selector
dial to 1
Change detection zone
Change detection zone
Change detection zone,
change site of installation
Use shrouds to define detection
zone precisely
Switch SensorLight OFF and back
ON again after 5 sec.
Firmly press terminal together
Change programme
see note on page 13
Claims under warranty shall only be accepted if the
product is sent fully assembled and well packed com-
plete with a brief description of the fault, a receipt or
invoice (date of purchase and dealer's stamp) to the
appropriate service centre.
Repair Service:
Our Customer Service Department will
36
repair faults not covered by warranty or
after the warranty period. Please send
the product well packed to your near-
est Service Centre.
- 15 -

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

L626 led

Tabla de contenido