Packaging Components - GRE AR-118 Manual De Instrucciones Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 7
INSTRUCTIONS FOR MONOBLOC FILTER
Read this manual thoroughly before installing the filter and carefully follow the instructions during installation and use.
Keep this manual for future reference regarding the operation of this apparatus.
• All electrical installations should comply with the following standard;
that refers "to the construction of electrical installations, both in indoor and outdoor swimming pools", or the
equivalent standard in force in each region or country.
• All filtering should follow the C 15-100 installation standard that stipulates that all electrical apparatus located at
less than 3.5 m. from the pool and freely accessible, should be supplied by a very low voltage of 12 V. All
apparatus supplied with 220 V should be located at least 3.5 m. from the swimming pool edge. Ask the
manufacturer for permission to make any modifications in one or more elements of the filtering system.
• The electrical installation should be performed by professional staff qualified in electrical installations.
• The apparatus must not be on while the pool is being used.
• Do not operate the apparatus unless it is properly primed.
• NEVER touch the filter when it is operating if you are wet or have wet hands.
• When handling the filter or valve, DISCONNECT the power supply.
• Make sure that the ground is dry before touching the electrical equipment.
• Do not install the filter where it could become wet, as it may cause electrocution.
• Do not allow children or adults to lean against or sit on the apparatus.
• If the supply flex of the apparatus is damaged, it should be replaced. Read the instructions carefully to replace
it. If in doubt, contact the technical service.

1 PACKAGING COMPONENTS

The monobloc which you have just purchased is a device which is especially planned and designed to be used in
elevated pools. As a result of its innovative design and excellent functionality, it provides you with the components
required to filter water: a single unit which includes filter and pump.
The main components of this monobloc are as follows:
Model
Pos.
Fig.
1
2
2
2
3
12
AR-118
4
5/8
5
4/7
6
9
7
11
8
3
9
3
AR-118
10
4/5
11
4/5
12
9
Check that your monobloc unit includes all of the components.
1.1 REQUIREMENTS FOR CORRECT INSTALLATION
This apparatus is easy to install and can be assembled by one adult in about 2 HOURS, taking care to correctly follow the
instructions detailed in the manual.
Only the following tools are required to correctly handle the filter components and to install it.
Task
Tighten the hose flanges
Cut the liner
SAFETY INSTRUCTIONS. READ CAREFULLY
NF EN 60-335-2-41
Amt.
1
Filter base unit
1
Filter body unit
1
Motorised pump 120W 220/230V 50Hz
1
Hose ø25 mm, 4.5 m length (feedback)
1
Hose ø3 2 mm, 4.5 m length (suction)
1
Hose ø25 mm, 0.30 m length (discharge)
1
Filtering cartridge
1
Feedback valve, coupling and nut with ø25 mm connection
1
Suction valve, coupling and nut with ø32 mm connection
4
Drag rings
4
Sealing gaskets
6
Hose securing clamps
NF C15-100
Name
Tool
7mm Stecker screwdriver
Cutter
3
ENGLISH
Alternative tool
Philips screwdriver
Knife

Publicidad

Tabla de contenido
loading

Tabla de contenido