asseMBlY and HOOK-uP InFOrMaTIOn
1. Heater model MH15T is packaged completely.
Propane cylinders (tanks) are not included with heater
model.
2. Remove heater from carton.
3. Use only vapor withdrawal LP gas cylinders constructed
for use with propane only (HD-5) and marked in
accordance with the specifications for lP gas cylinders
of the u.S. Department of transportation
(DOT SPEC. 39).
4. This heater must be used only with a vapor withdrawal
LP gas bulk tank equipped with a standard POL valve
– do not use this heater on bulk tanks greater than 20
pounds LPG capacity (50 pounds water capacity).
5. (see figure 2.)
Be sure heater is facing away from tank.
Insert regulator connector into tank valve outlet
fitting and turn left (counterclock-wise) until fully
tightened. Do not overtighten. (See Figure 2a)
Place heater support around venturi and slide clip
ends onto propane cylinder collar. Use 1/4"-20 x
35mm screw and wing nut to secure heater sup-
port onto venturi tube. (See Figure 2b)
6. Operate only on a stable, level surface.
7. Open propane tank valve slowly.
8. Check all fittings for leaks. Apply a 50/50 mixture of
liquid soap and water to all joints. Bubbles forming
indicate a leaking connection. Correct all leaks before
proceeding.
Warning
Never touch heater while in operation to avoid injury.
Move heater by grasping the propane cylinder carefully.
9. the heater should be inspected before each use and at
least annually by a qualified service person.
10. Minimum inlet gas pressure is 20 psi.
11. Maximum inlet gas pressure is 120 psi
(equivalent to an ambient temperature of 75°F [24° C]).